OSHA Inspection: SUBZERO INSULATION & REFRIGERATION TECHNOLOGIES LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SUBZERO INSULATION & REFRIGERATION TECHNOLOGIES LLC in 144 VAN DYKE STREET, BROOKLYN, NY 11231 (NAICS 333415). OSHA activity number 331914333.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Subzero Insulation & Refrigeration Technologies LLC for free Get an email when a new federal OSHA severe-injury report for Subzero Insulation & Refrigeration Technologies LLC is published. One employer, no account, unsubscribe in one click.
Site address
144 VAN DYKE STREET
City
BROOKLYN
State
NY
ZIP
11231
Mailing
144 VAN DYKE STREET, BROOKLYN, NY 11231
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333415
Employees
18
Ownership type
A

17 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 18 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $3,300 · Current $3,300
29 CFR 1910.22(a)(1): All place(s) of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:      a) Subzero Insulation & Refrigeration Technologies - In the carpentry shop saw dust was present on the floor. Acumulation of dust was visible on the horizontal surfaces of the shop such as but no limited to electrical conduit and overhead lights. Other areas of the worksite were also covered with dust generated from cutting and sanding the dried foam and the antimicrobial-treated dry wall. The condition was noted on or about 02/15/12.      NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • · F (S) $3300
  • · C (S) $3300
  • · Z (S) $3300

1910.23 C

Serious Gravity 10 2 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $4,620 · Current $3,300 Reduced
29 CFR 1910.23(c): Every open sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded:          a) Subzero Insulation & Refrigeration Technologies - Employees were observed working from the top of a van roof, during which they were exposed to fall hazards of 8 ft 9 inches to the to the work floor below.       NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • · F (S) $3300
  • · C (S) $4620
  • · Z (S) $4620

1910.134 G01 I

Deleted Serious Gravity 5 1 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $3,300 · Current $0 Reduced
29 CFR 1910.134(g)(1)(i): The employer permitted respirators with tight-fitting facepieces to be worn by employees who have facial hair that comes between the sealing surface of the facepiece and the face:      a) Subzero Insulation & Refrigeration Technologies - The helper working with the sprayer was required to use tight fitting full face air purifying respirator during the application of 2-part isocyanate insulation foam, and paint the retrofitted refrigerated vans. During such operations the helper wore his respirator over facial hair. The condition was noted on or about 02/15/12.      NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • · F (S) $0
  • · C (S) $3300
  • · Z (S) $3300

1910.141 D01

Serious Gravity 1 1 instance 13 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $1,980 · Current $250 Reduced
29 CFR 1910.141(d)(1): Washing facilities were not maintained in a sanitary condition:        a) Subzero Insulation & Refrigeration Technologies - The restroom located in the basement of the facility was not maintained in sanitary condition. Employees performing work operations to include but not limited to applying spray foam, painting, welding,  woodworking and cleaning were not provided with a clean and sanitary bathroom as the floor was visibly dirty. The condition was noted on or about 02/15/12.      NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • · F (S) $250
  • · C (S) $1980
  • · Z (S) $1980

1910.141 D02 II

Serious Gravity 1 13 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(2)(ii): Each lavatory was not provide with hot and cold running water, or tepid running water:      a) Subzero Insulation & Refrigeration Technologies - The restroom located in the basement of the facility was not maintained in sanitary condition. Employees performing work operations to include but not limited to applying spray foam, painting, welding,  woodworking and cleaning were not provided with hot or tepid running water water. The condition was noted on or about 02/15/12.        NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • · F (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.141 D02 III

Serious Gravity 1 13 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(2)(iii): Lavatories were not provided with hand soap or similar cleansing agent:        a) Subzero Insulation & Refrigeration Technologies - The restroom located in the basement of the facility was not maintained in sanitary condition. Employees performing work operations to include but not limited to applying spray foam, painting, welding,  woodworking and cleaning were not provided with hand soap or similar cleansing agent. The condition was noted on or about 02/15/12.      NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • · F (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.141 D02 IV

Serious Gravity 1 13 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(2)(iv): Lavatories were not provided with individual hand towels or sections thereof, of cloth or paper, warm air blowers or clean individual sections of continuous cloth toweling:          a) Subzero Insulation & Refrigeration Technologies - The restroom located in the basement of the facility was not maintained in sanitary condition. Employees performing work operations to include but not limited to applying spray foam, painting, welding,  woodworking and cleaning were not provided with means to dry their hands when using the restroom. The condition was noted on or about 02/15/12.      NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • · F (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.213 C01

Serious Gravity 10 1 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $4,620 · Current $4,620
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:      a) Subzero Insulation and Refrigeration Technologies - Employees used a Rigid table saw to cut wood used to frame vehicle interiors. The saw wasnot guarded with a hood. The condition was noted on or about 02/15/12.      NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • · F (S) $4620
  • · C (S) $4620
  • · Z (S) $4620

1910.213 B03

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $4,620 · Current $1,500 Reduced
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure:    a) Subzero Insulation -  Carpenter operate power equipment such as Makita miter saw for cutting wood used to frame vehicle interiors. The condition was noted on or about 02/15/12.      NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • · F (S) $1500
  • · C (S) $4620
  • · Z (S) $4620

1910.242 B

Serious Gravity 10 5 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $4,620 · Current $1,500 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:       a) Subzero Insulation and Refrigeration Technologies -  Employees use compressed air at 120 psi to clean themselves off after work operations. The condition was noted on or about 02/15/12.      NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • · F (S) $1500
  • · C (S) $4620
  • · Z (S) $4620

1910.305 G02 III

Serious Gravity 5 3 instances 4 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $2,640 · Current $1,250 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:       a) Subzero Insulation and Refrigeration Technologies - The compressor for breathing air was energized by a flexible cord that showed signs of strain. The employer did not ensure that the flexible cord was connected to the device and fitted so the tension would not be transmitted to the joints or terminal screw. The condition was noted on or about 02/15/12.    b) Subzero Insulation and Refrigeratoins Technologies - The Hilti WSJ 750-ET Orbital action jig saw was being used by employees to cut wood did not have strain relief on its cord. The conditoin was noted on or about 02/23/12.    c) Subzero Insulation and Refrigeratoins Technologies - An extensoin cord used to power a Makita 5007F Circular Saw did not have strain relief. The condition was noted on or about 02/23/12.      NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • · F (S) $1250
  • · C (S) $2640
  • · Z (S) $2640

1910.305 J04 V

Deleted Serious Gravity 5 18 exposed
Issued
Aug 10, 2012
Penalty
Initial $2,805 · Current $0 Reduced
29 CFR 1910.305(j)(4)(v): Disconnecting means for motors, motor circuits, and controllers were not readily accessible:        a) Subzero Insulation and Refrigeration Technologies - The panel box in the carpenters' shop was blocked by tables and plywood. The condition was noted on or about 02/15/12.        NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY  DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT  CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS  VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (3)
  • · F (S) $0
  • · C (S) $2805
  • · Z (S) $2805

1910.1200 E01

Serious Gravity 5 15 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $3,300 · Current $1,000 Reduced
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):       a) Subzero Insulation & Refrigeration Technologies - Despite having a written Hazard Communication Program the employer did not implement the different components of the program. The condition was noted on or about 02/15/12.      NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • · F (S) $1000
  • · C (S) $3300
  • · Z (S) $3300

1910.1200 G01

Serious Gravity 5 15 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Employer did not have a material safety data sheet in the workplace for each hazardous chemical which they use:      a) Subzero Insulation & Refrigeration Technologies - The employer failed to implement  their written hazard communication program for employees exposed to welding gases, refrigerant, wood dust, isocyanate spray paint and foam. The employer failed to maintain MSDS(s) for chemicals used by workers to include but no limited to welding gases, antimicrobial dry wall (MDF), and citrus clean. The condition was noted on or about 02/15/12.      NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • · F (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.1200 H01

Serious Gravity 5 15 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided information and training as specified in 29 CFR 1910.1200(h)(2) and (3) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area:        a) SubZero Insulation - Employees use and are exposed to hazardous substances including but not limited to isocyanates, argon, adhesives and refrigerants. Information and training shall include:             - the location and availability of the written hazard communication program;          - the physical and health hazards of the chemicals used;          - explanation of Material Safety Data Sheets (MSDS);          - methods and observations used to detect the presence of hazardous chemicals and required emergency response.    The condition was noted on or about 02/15/12.    NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19
Recent events (3)
  • · F (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.134 H01 I

Repeat Gravity 5 1 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $16,500 · Current $4,000 Reduced
29 CFR 1910.134(h)(1)(i): Respirators issued for the exclusive use of an employee were not cleaned and disinfected as often as necessary to be maintained in sanitary condition:     a) Subzero Insulation & Refrigeration Technologies - Employee helping the sprayer was required to use tight fitting full face air purifying respirator while spraying 2-part isocyanate insulation foam, and painting the retrofitted refrigerated vans. The employer permited the employees to wear a respirator that was not clean and desinfected. The condition was noted on or about 02/15/12.      Subzero Insulation & Refrigeration Technologies was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard which was contained in OSHA Inspection Number 315478537, Citation Number 1, Item Number 6, Group a, issued December 12, 2011, with respect to a workplace located at Jacksonville Florida. The citation became final order on January 5, 2012.    NOTE:  CERTIFICATION AND DOCUMENTATION OF ABATEMENT MUST BE SUBMITTED FOR THIS CITATION ITEM AS REQUIRED BY 29 CFR 1903.19.
Recent events (3)
  • · F (R) $4000
  • · C (R) $16500
  • · Z (R) $16500

1904.32 A02

Deleted Other-than-serious 15 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $660 · Current $0 Reduced
1904.32(a)(2): The Summary of Work-Related Injuries and Illnessess (OSHA Form 300A or equivalent) was not created, certified, or posted:      a) Subzero Insulation & Refrigeration Technologies - The OSHA 300A for calendar year 2011 was not certified or posted per 29 CFR 1904.32(b)(6). The condition was noted on or about 02/15/12.     b) Subzero Insulation & Refrigeration Technologies - The total hours worked by employees covered by the OSHA 300 Log for calendar year 2011 was not entered on the OSHA 300A for calendar year per 29 CFR 1904.32(b)(1) through (b)(6). The condition was noted on or about 02/15/12.       NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19.
Recent events (3)
  • · F (O) $0
  • · C (O) $660
  • · Z (O) $660

View Subzero Insulation & Refrigeration Technologies LLC's full OSHA safety record →