Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: SUBZERO INSULATION & REFRIGERATION TECHNOLOGIES LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SUBZERO INSULATION & REFRIGERATION TECHNOLOGIES LLC in 144 VAN DYKE STREET, BROOKLYN, NY 11231 (NAICS 333415). OSHA activity number 331921635.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Subzero Insulation & Refrigeration Technologies LLC for free Get an email when a new federal OSHA severe-injury report for Subzero Insulation & Refrigeration Technologies LLC is published. One employer, no account, unsubscribe in one click.
Site address
144 VAN DYKE STREET
City
BROOKLYN
State
NY
ZIP
11231
Mailing
144 VAN DYKE STREET, BROOKLYN, NY 11231
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333415
Employees
20
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $3,300 · Current $3,300
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.    Location: Framing area inside the shop;    On or about 02/23/12;    a) Employee was using a Makita 5007F 7-1/4-Inch Circular Saw that was missing its guard.
Recent events (3)
  • · F (S) $3300
  • · C (S) $3300
  • · Z (S) $3300

1910.304 B03 II A

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $3,300 · Current $0 Reduced
29 CFR 1910.304(b)(3)(ii)(A): All 125-volt, single-phase, 15-, 20-, and 30-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by personnel shall have ground-fault circuit-interrupter protection for personnel.    Location:  Finishing area/ Maintenance shop;    On or about 02/23/12;    a) Employee was using a WSJ 750-ET Orbital action jig saw and was not protected by a ground-fault circuit-interrupter or an assured equipment grounding program.
Recent events (3)
  • · F (S) $0
  • · C (S) $3300
  • · Z (S) $3300

1910.305 B02 I

Serious Gravity 5 1 instance 20 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $2,640 · Current $1,000 Reduced
29 CFR 1910.305(b)(2)(i):  All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.    Location: Inside the shop;    On or about 02/23/12;    a)    The outlet box used to power a refrigerator and a microwave was missing a faceplate.
Recent events (3)
  • · F (S) $1000
  • · C (S) $2640
  • · Z (S) $2640

1910.133 A01

Repeat Gravity 5 1 instance 1 exposed
Issued
Aug 10, 2012
Abate by
Aug 24, 2012
Penalty
Initial $13,200 · Current $4,000 Reduced
29 CFR 1910.133(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.    Location: Finishing area/ Maintenance shop.    On or about 02/23/12;    a) Employee was not using protective eye equipment while cutting wood with powered tools.    REPEAT STATEMENT    SUBZERO INSULATION & REFRIGERATION TECHNOLOGIES, LLC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD,  OR ITS EQUIVALENT STANDARD, 1910.133(a)(1) WHICH WAS CONTAINED  IN OSHA INSPECTION NUMBER 315478537, CITATION NUMBER 1, ITEM NUMBER 1B AND WAS AFFIRMED AS FINAL ORDER ON 01/05/12, WITH RESPECT TO A WORKPLACE LOCATED AT 6215 WILSON BOULEVARD #4, JACKSONVILLE, FL 32210.
Recent events (3)
  • · F (R) $4000
  • · C (R) $13200
  • · Z (R) $13200

View Subzero Insulation & Refrigeration Technologies LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331921635.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.