Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: EMPIRE STEEL ERECTORS, LP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EMPIRE STEEL ERECTORS, LP in 5800 KIRBY, HOUSTON, TX 77005 (NAICS 236210). OSHA activity number 332428986.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Empire Steel Erectors, LP for free Get an email when a new federal OSHA severe-injury report for Empire Steel Erectors, LP is published. One employer, no account, unsubscribe in one click.
Site address
5800 KIRBY
City
HOUSTON
State
TX
ZIP
77005
Mailing
P.O.BOX 3653, HUMBLE, TX 77347
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
110
Ownership type
Private (A)

5 citations on file for this inspection.

1926.251 A01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Mar 28, 2012
Abate by
Apr 27, 2012
Penalty
Initial $3,960 · Current $0 Reduced
29 CFR 1926.251(a)(1): Rigging equipment for material handling shall be inspected prior to use on each shift and asnecessary during its use to ensure that it is safe. Defective rigging equipment shall be removed from service.    East side of parking lot; a defective wire rope, bent in several places was rigged to position a steel beam, was not inspected and removed from service, exposing employees to struck by hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3960

1926.251 A04

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Mar 28, 2012
Abate by
Apr 27, 2012
Penalty
Initial $2,970 · Current $0 Reduced
29 CFR 1926.251(a)(4): Special custom design grabs, hooks, clamps, or other lifting accessories, for such units as modularpanels, prefabricated structures and similar materials, shall be marked to indicate the safe working loads and shall be proof-tested prior to use to125 percent of their rated load.    East side of parking lot; a wire rope, crane hook, and clamps that were used to position a steel beam were not marked to indicate the safe working load, exposing employees to struck by hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2970

1926.1412 E02

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Mar 28, 2012
Abate by
Apr 27, 2012
Penalty
Initial $4,950 · Current $0 Reduced
29 CFR 1926.1412(e)(2): Equipment must not be used until an inspection under this paragraph demonstrates that no corrective action under paragraphs (d)(2) and (3) of this section is required.    East side of parking lot; Employer inspected, then operated a Ford 550 mobile crane truck before crane corrections and adjustments were made, exposing employees to struck by hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4950

1926.1412 E03 I

Other-than-serious 1 instance 2 exposed
Issued
Mar 28, 2012
Abate by
Apr 27, 2012
Penalty
Initial $0 · Current $4,950
29 CFR 1926.1412(e)(3)(i): The following information must be documented and maintained by the employer that conducts the inspection:    East side of parking lot; Employer did not document and maintain records of monthly crane inspections, exposing employees to struck by hazards.
Recent events (2)
  • · I (O) $4950
  • · Z (S) $0

1926.1433 D04 III

Other-than-serious 1 instance 2 exposed
Issued
Mar 28, 2012
Abate by
Apr 27, 2012
Penalty
Initial $2,970 · Current $2,970
29 CFR 1926.1433(d)(4)(iii): The latch must close the throat opening and be designed to retain slings or other lifting devices/accessories in the hook when the rigging apparatus is slack.    East side of parking lot; a crane hook was used to position a steel beam, where the safety latch was defective and did not close the throat opening of the hook, exposing employees to struck by hazards.
Recent events (2)
  • · I (O) $2970
  • · Z (S) $2970

View Empire Steel Erectors, LP's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 332428986.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.