OSHA Inspection: HACKETTSTOWN REGIONAL MEDICAL CENTER
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HACKETTSTOWN REGIONAL MEDICAL CENTER in 651 WILLOW GROVE ST., HACKETTSTOWN, NJ 07840 (NAICS 622110). OSHA activity number 332801901.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HACKETTSTOWN REGIONAL MEDICAL CENTER
- Site address
- 651 WILLOW GROVE ST.
- City
- HACKETTSTOWN
- State
- NJ
- ZIP
- 07840
- Mailing
- 651 WILLOW GROVE ST., HACKETTSTOWN, NJ 07840
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 622110
- Employees
- 800
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1910.147 C04 II
- Issued
- May 11, 2012
- Abate by
- Jul 5, 2012
- Penalty
- Initial $3,400 · Current $2,210 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D)(h): a/ Hackettstown Reg. Med. Ctr./Hackettstown NJ Site - Facility/Maintenance Areas: At the time of this inspection the sites lockout procedure had not been completed, in that, specific steps to de-energize the equipment/machinery, control of locking devices, authorized maintenance employees/helpers, rules and techniquies were not developed and documented. Machinery/equipment include but not limited to HVAC Systems with Motors, Boilers, Compressors, Industrial Washers/Dryers, etc. Observed on/or about 3/9/2012.
Recent events (2)
- · I (S) $2210
- · Z (S) $3400
1910.147 C06 II
- Issued
- May 11, 2012
- Abate by
- Jul 25, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a/ Hackettstown Reg. Med. Ctr./Hackettstown NJ Site - Facility/Maintenance Areas: Employees who are required to perform maintenance/service on equipment/machinery had not been evaluated by the employer to ensure proper lockout procedures were being followed. Machines incllude but not limited to compressors, HVAC systems, industrial washers/dryers, etc. Observed on/or about 3/9/2012.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.333 B02 I
- Issued
- May 11, 2012
- Abate by
- Jul 5, 2012
- Penalty
- Initial $4,250 · Current $2,763 Reduced
General-duty citation text
29 CFR 1910.333(b)(2)(i): The employer did not make a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 available for inspection by employees: a/ Hackettstown Reg. Med. Ctr./Hackettstown NJ Site - Facility/Maintenance Areas: Where employees are required to perform limited (standard and live) electrical maintenance on machinery/equipment, OSHA regulation 1910.333(b) and/or an equivalent was not made available to them. Observed on/or about 3/9/2012.
Recent events (2)
- · I (S) $2763
- · Z (S) $4250
1910.335 A01 I
- Issued
- May 11, 2012
- Abate by
- Jun 25, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed: a/ Hackettstown Reg. Med. Ctr./Hackettstown NJ Site - Facility/Maintenance Areas: Where employees are required (on a limited basis) to perform live electrical testing and/or trouble-shooting on machinery/equipment, protectors including but not limited to approved electrical gloves (ANSI rated 00 or 01 - minimum 500 volts), insulated tools, etc. were not provided for each electrical worker. Observed on/or about 3/9/2012.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.145 C03
- Issued
- May 11, 2012
- Abate by
- Jun 25, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.145(c)(3): Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s): a/ Hackettstown Reg. Med. Ctr./Hackettstown NJ Site - Facility (Including but not limited to HVAC Systems #7and #8): Where employees are required to enter HVAC systems for cleaning purposes, the space where the cleaning is performed has not been provided with signs reading "confined space" and/or other approved classification. Observed on/or about 3/9/2012.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.146 C01
- Issued
- May 11, 2012
- Abate by
- Jul 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: a/ Hackettstown Reg. Med. Ctr./Hackettstown NJ Site - Facility (Including but not limited to HVAC systems #7and #8): Where employees are required to enter HVAC systems for cleaning purposes, the space where the cleaning is performed has not been evaluated to determine if it is a "permit required" confined space. Observed on/or about 3/9/2012.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.303 F
- Issued
- May 11, 2012
- Abate by
- Aug 30, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f): Each service, feeder and branch circuit, at its disconnecting means or over current device, was not legibly marked to indicate its purpose: a/ Hackettstown Reg. Med. Ctr./Hackettstown NJ Site - Facility (Including but not limited to the Fourth Floor, Pent House, Boiler Room, Maintenance Areas): Where electrical boxes/breakers had typed markings to indicate their character/function, the print was not large enough to be readily seen in the event the equipment needs to be accessed. The equipment include but not limited to HVAC Systems with Motors, Boilers, lights, Compressors, Industrial Washers/Dryers, maintenance equipment - bench grinders, etc. Observed on/or about 3/9/2012.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Hackettstown Regional Medical Center
View Hackettstown Regional Medical Center's full OSHA safety record →
More inspections in this industry (NAICS 622110)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 332801901.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.