Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NAVY EXCHANGE SERVICE COMMAND

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NAVY EXCHANGE SERVICE COMMAND in 2260 CALLAGAN HIGHWAY BLDG. 3187A, 3379, 3155, SAN DIEGO, CA 92136 (NAICS 452111). OSHA activity number 332811462.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Navy Exchange Service Command — free Get an email when a new federal OSHA severe-injury report for Navy Exchange Service Command is published. One employer, no account, unsubscribe in one click.
Site address
2260 CALLAGAN HIGHWAY BLDG. 3187A, 3379, 3155
City
SAN DIEGO
State
CA
ZIP
92136
Mailing
2260 CALLAGAN HIGHWAY BLDG. 3187A, SAN DIEGO, CA 92136
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
452111
Employees
200
Ownership type
D

10 citations on file for this inspection.

1910.303 B02

Serious Gravity 5 1 instance 200 exposed
Issued
Apr 24, 2012
Abate by
Apr 25, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    8th Street Will Call, Ezekiel's Work Area: On March 9, 2012, and at times prior thereto, a power tap had been tied to a steel beam and used to permanently energize extension cords.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 3 instances 200 exposed
Issued
Apr 24, 2012
Abate by
Apr 25, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used for purposes prohibited by subparagraphs (a) through (f) of this section:    8th Street Will Call, Ezekiel's Work Area: On March 9, 2012, and at times prior thereto, three extensions cords were used in lieu of permanent wiring.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV B

Serious Gravity 5 1 instance 200 exposed
Issued
Apr 24, 2012
Abate by
Apr 25, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords were used and run through holes in walls, ceilings, or floors:    8th Street Will Call: On March 9, 2012, and at times prior thereto, a spliced white extension cord was run through a hole in the wall separating the main work area and Ezekiel's work area.
Recent events (1)
  • — Z (S) $0

1910.305 G02 II

Serious Gravity 5 1 instance 200 exposed
Issued
Apr 24, 2012
Abate by
Apr 25, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were used were in continuous lengths with a splice or tap:    8th Street Will Call: On March 9, 2012, and at times prior thereto, a white extension cord had been spliced together and the inner conductors were exposed along the wall in the main work area.
Recent events (1)
  • — Z (S) $0

1910.305 B02

Serious Gravity 5 1 instance 200 exposed
Issued
Apr 24, 2012
Abate by
Apr 25, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    8th Street Will Call/FISC Wall: An junction box inches from the ground, next to an exit, was not provided with a cover and the live inner conductors were exposed.
Recent events (1)
  • — Z (S) $0

1910.332 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 24, 2012
Abate by
Jun 6, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety related work practices required by 29 CFR 1910.331 through 1910.335 that pertained to their respective job assignments:    On March 9, 2012,nd at times prior thereto, the electrician had not been trained regarding what work practices and protective equipment was required to protect them against electric shock, arc flash and arc blast hazards while performing live electrical work, live trouble-shooting and verifying whether or not electrical equipment was properly de-energized.
Recent events (1)
  • — Z (S) $0

1910.333 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 24, 2012
Abate by
Jun 6, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.333(a)(1): Live parts to which an employee may be exposed were not de-energized before the employee worked on or near them:    On March 9, 2012,and at times prior thereto, the employer allowed live work including but not limited to live cable installation.
Recent events (1)
  • — Z (S) $0

1910.333 A02

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 24, 2012
Abate by
Jun 6, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.333(a)(2): Where exposed live parts where not de-energized, other safety related work practices were not used to protect employees who could be exposed to the electrical hazards involved:    On March 9, 2012,and at times prior thereto, the employer had not developed and implemented an Electrical Safety Related Work Practices Program to adress hazards caused by arc flash, arc blast and electric shock in the facility. Employees conducted live cables installations and ballast chages, live trouble-shooting and tested electrical equipment to ensure that it was properly de-energized.
Recent events (1)
  • — Z (S) $0

1910.335 A01 II

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 24, 2012
Abate by
Jun 6, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(1)(ii): Employees working in areas where there were potential electrical hazards were not provided with and/or did not use, electrical personal protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed:    On March 9, 2012,and at times prior thereto, personal protective equipment such as, but not limited to, voltage rated gloves, FR clothing, and face shields were not provided to employees who performed live electrical work, including trouble-shooting, or who verified that electrical equipment was properly de-energized.
Recent events (1)
  • — Z (S) $0

1910.335 A02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 24, 2012
Abate by
Jun 6, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.335(a)(2)(i): :When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have contact with such conductors or parts:    On March 9, 2012,and at times prior thereto, voltage rated tools were not provided to electrician personnel when working near energized electrical equipment.