Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: CAPRON MANUFACTURING COMPANY, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of CAPRON MANUFACTURING COMPANY, INC. in 200 N. BURR OAK ROAD, CAPRON, IL 61012 (NAICS 332812). OSHA activity number 332817956.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Capron Manufacturing Company, INC. — free Get an email when a new federal OSHA severe-injury report for Capron Manufacturing Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
200 N. BURR OAK ROAD
City
CAPRON
State
IL
ZIP
61012
Mailing
200 N. BURR OAK ROAD, CAPRON, IL 61012
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
50
Ownership type
A

2 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 13, 2012
Abate by
Aug 24, 2012
Penalty
Initial $3,500 · Current $2,450 Reduced

Hazardous substances 8111

29 CFR 1910.95(c)(1):     The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:    On March 26, 2012, the Powered Paint Applicator was exposed during a 424 minute sample period to an 8 hour time weighted average of 87.6 dBA or a dose of 71.5% of the permissible exposure limit.  Zero exposure was assumed during the unsampled time period.
Recent events (3)
  • — F (S) $2450
  • — C (S) $3500
  • — Z (S) $3500

1910.134 D01 III

Other-than-serious 1 instance 5 exposed
Issued
Jul 13, 2012
Abate by
Aug 24, 2012
Penalty
Initial $1,785 · Current $0 Reduced
29 CFR 1910.134(d)(1)(iii):     The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminants chemical state and physical form:      Porcelain Application Area, employees applying the following powder coatings, are required to wear 1/2 mask respirators, however an evaluation had not been made of the employees' exposure level.    a)  Pemco Black Base Coat and Porcelain Enamel Groundcoat to metal parts are required to wear 1/2 mask respirators, however an evaluation had not been made of the employees' exposure level.        Abatement certification is required of this item in accordance witrh the requirements of 29 CFR 1903.19(c).
Recent events (3)
  • — F (O) $0
  • — C (S) $1785
  • — Z (S) $1785

View Capron Manufacturing Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332817956.