BROOKLYN, NY ·
OSHA Inspection: BAYPORT CONSTRUCTION CORP
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of BAYPORT CONSTRUCTION CORP in 217 GRAND STREET, BROOKLYN, NY 11211 (NAICS 238140). OSHA activity number 332823475.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BAYPORT CONSTRUCTION CORP
- Site address
- 217 GRAND STREET
- City
- BROOKLYN
- State
- NY
- ZIP
- 11211
- Mailing
- 14B 53RD STREET SUITE 7B, BROOKLYN, NY 11232
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 18
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1926.451 E04 V
- Issued
- Sep 6, 2012
- Penalty
- Initial $2,400 · Current $4,000
General-duty citation text
29 CFR 1926.451(e)(4)(v): The ends of stairrail systems and handrails was not constructed so that they do not constitute a projection hazard. Located at 217 Grand Street, Brooklyn, NY On or about 3/22/2012 a) Workers using a 6 frame high tubular welded frame scaffold stairway and each level of the stairway was missing an adequate handhold for employees grasping the railing creating a projection hazard.
Recent events (2)
- · I (O) $4000
- · Z (S) $2400
1926.451 E07
- Issued
- Sep 6, 2012
- Penalty
- Initial $3,300 · Current $4,000
General-duty citation text
29 CFR 1926.451(e)(7): Steps and rungs of ladder and stairway type access did not line up vertically with each other between rest platforms. Located at 217 Grand Street, Brooklyn, NY On or about 3/22/2012 a) Workers using a tubular welded frame scaffold stairway and the steps were not flat and vertical with each other on the 1st and second level.
Recent events (2)
- · I (O) $4000
- · Z (S) $3300
1926.451 F07
- Issued
- Sep 6, 2012
- Penalty
- Initial $3,300 · Current $4,000
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. Located at 217 Grand Street, Brooklyn, NY On or about 3/22/2012 a) Workers worked from and accessed the roof area using a tubular welded frame scaffold which was not inspected by a competent person during its erection. The stairway and the steps were not flat and vertical, was missing handrails, and was missing midrails and endrails.
Recent events (2)
- · I (O) $4000
- · Z (S) $3300
1926.451 G04 XV
- Issued
- Sep 6, 2012
- Penalty
- Initial $4,620 · Current $4,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(xv): Crossbracing used in place of a midrail was unacceptable because the crossing point of two braces is between 20 inches (0.5 m) and 30 inches ((0.8 M) above the work platform or as a toprail when the crossing point of two braces is not between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform or as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. The endpoints at each upright were more than 48 inches (1.3 m) apart. Located at 217 Grand Street, Brooklyn, NY On or about 3/22/2012 a) Employee worked from and accessed the roof area using a tubular welded frame scaffold, and crossbracing used in place of a toprail was not between 38 and 48 inches . Employees exposed to a fall of approximatley 30 ft.
Recent events (2)
- · I (O) $4000
- · Z (S) $4620
1926.501 B01
- Issued
- Sep 6, 2012
- Penalty
- Initial $8,400 · Current $4,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Located at 217 Grand Street, Brooklyn, NY On or about 3/22/2012 a) Employee on the edge of a building roof and the employee was not protected from falling approximately 40 feet. Employee was located on the northwest corner of the building and was not protected from falling with a personal fall arrest system. REPEAT STATEMENT (FIRST REPEAT) Bayport Construction Corp. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, ITS EQUIVALENT, OR ESSENTIALLY SIMILAR STANDARD, 29 CFR 1926.501(b)(1) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER #313980021 CITATION NUMBER 01, ITEM NUMBER 009, ISSUE ON 06/23/2010 NOTE: FINAL ORDER DATE 08/06/2010
Recent events (2)
- · I (O) $4000
- · Z (R) $8400
More inspections at Bayport Construction Corp
View Bayport Construction Corp's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 332823475.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.