VICTOR, NY ·
OSHA Inspection: TAMBE METAL PRODUCTS INCORPORATED
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TAMBE METAL PRODUCTS INCORPORATED in 7500 MAIN STREET FISHERS, VICTOR, NY 14564 (NAICS 332322). OSHA activity number 332824440.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TAMBE METAL PRODUCTS INCORPORATED
- Site address
- 7500 MAIN STREET FISHERS
- City
- VICTOR
- State
- NY
- ZIP
- 14564
- Mailing
- P. O. BOX 30, VICTOR, NY 14564
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 53
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.212 A01
- Issued
- May 31, 2012
- Abate by
- Jun 30, 2012
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Secondary Round Area, on or about 3/20/12: Zip Flange Machine, in-running feed rollers were not guarded. b) Duct Coil Line, on or about 4/5/12: Decoiler, rotating clutch was not adequately guarded. c) Duct Coil Line, on or about 4/5/12: Conveyor was not provided with guarding at the in-running points where the belts and rollers meet. d) Press Brake Area, on or about 4/5/12: Sibley Southbend single spindle drill press was not provided with a chuck guard. e) Duct Coil Line, on or about 4/5/12: Discharge conveyor was not provided with guarded at the in-running points were the belts and rollers meet.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.219 B01
- Issued
- May 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(b)(1): Flywheels. Flywheels located so that any part is seven (7) feet or less above floor or platform shall be guarded in accordance with the requirements of this subparagraph: a) Press Area, on or about 3/20/12: Cincinati 120-ton Press Brake flywheel was not adequately guarded.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.219 F01
- Issued
- May 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii): a) Secondary Round Area, on or about 3/20/12: The Zip Flange machine was not provided with guarding at the in-running points of the infeed gears.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.219 F03
- Issued
- May 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: a) Duct Coil Line, on or about 4/5/12: Near the decoiler, chain and sprocket was not provided with a guard.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 B01
- Issued
- May 31, 2012
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) Secondary Round Area, on or about 3/20/12: Zip flange machine, 480 volt control panel on/off handle was broken and employees were accessing the inside of the panel to turn the machine on and off.
Recent events (2)
- · I (S) $2100
- · Z (S) $3500
1910.303 B02
- Issued
- May 31, 2012
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Lock Former Area, on or about 3/20/12: Pendant cord with a metal receptacle box attached was used to power equipment. The metal box is listed for permanent mounting only. b) Turning Vane Area, on or about 3/20/12: Pendant cord with a metal receptacle box attached used to power equipment. The metal box is listed for ermanent mounting only.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
More inspections at Tambe Metal Products Incorporated
View Tambe Metal Products Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 332824440.