Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HEB DISTRIBUTION CENTER

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HEB DISTRIBUTION CENTER in 4710 N PAN AM EXPRESSWAY, SAN ANTONIO, TX 78218 (NAICS 445110). OSHA activity number 332831940.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch HEB Distribution Center — free Get an email when a new federal OSHA severe-injury report for HEB Distribution Center is published. One employer, no account, unsubscribe in one click.
Site address
4710 N PAN AM EXPRESSWAY
City
SAN ANTONIO
State
TX
ZIP
78218
Mailing
4710 N PAN AM EXPRESSWAY, SAN ANTONIO, TX 78218
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
445110
Employees
150
Ownership type
A

3 citations on file for this inspection.

1910.23 C01

Other-than-serious 1 instance 2 exposed
Issued
Mar 30, 2012
Abate by
Apr 20, 2012
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:     a)  On or about 03/06/12 and at times prior thereto, employee(s) were exposed to falling from a working surface of approximately 11 feet high to the concrete ground level below while working on top of the tank.
Recent events (2)
  • — I (O) $0
  • — Z (S) $7000

1910.219 C04 II

Serious Gravity 5 2 instances 6 exposed
Issued
Mar 30, 2012
Penalty
Initial $4,000 · Current $4,000
29 CFR 1910.219(c)(4)(ii): Unused keyways were not filled up or covered:    a) On or about 03/06/12 and at times prior thereto, employees work near the #1 filler with a rotating shaft with a keyway exposing employees to lacerations and/or amputation hazards.    b) On or about 03/06/12 and at times prior thereto, employees work near the #2 filler with a rotating shaft with a keyway exposing employees to lacerations and/or amputation hazards.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $4000

1910.305 B01 I

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 30, 2012
Penalty
Initial $6,000 · Current $6,000
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter were not effectively closed:    a) On or about 03/06/12 and at times prior thereto, electrical conduit was pulled away from the #1 Caser exposing employee(s) to electrical shock and/or electrocution hazards.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $6000

View HEB Distribution Center's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332831940.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.