OSHA Inspection: FLEET READINESS CENTER

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of FLEET READINESS CENTER in BUILDING 94, CORONADO, CA 92135 (NAICS 811310). OSHA activity number 332836998.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fleet Readiness Center for free Get an email when a new federal OSHA severe-injury report for Fleet Readiness Center is published. One employer, no account, unsubscribe in one click.
Site address
BUILDING 94
City
CORONADO
State
CA
ZIP
92135
Mailing
BUILDING 466, CORONADO, CA 92135
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
500
Ownership type
D

7 citations on file for this inspection.

1910.1025 H01

Serious Gravity 10 32 instances 500 exposed
Issued
Aug 30, 2012
Abate by
Dec 31, 2013
Penalty
Initial $0 · Current $0

Hazardous substances BWPB

29 CFR 1910.1025(h)(1): All surfaces shall be maintained as free as practicable of accumulations of lead:    a) At Bldg. 94, Quickie shop, top of Dustron grind booth 039809 - On or about 2/16/12, lead dusts were allowed to accumulate.     b) At Bldg. 94, Quickie shop, top of panel of Dustron 039809 grind booth - On or about 2/16/12, lead dusts were allowed to accumulate.    c) At Bldg. 94, Wing Shop, Dustron grind booth floor - On or about 2/16/12, lead dusts were allowed to accumulate.     d) At Bldg. 94, Wing shop, top of black metal cabinet - On or about 2/16/12, lead dusts were allowed to accumulate.     e) At Bldg. 94, Bldg. 94, Wing shop, cart - On or about 2/16/12, lead dusts were allowed to accumulate.     f) At Bldg. 94, South lunch room, top of Dole juice dispenser - On or about 2/16/12, lead dusts were allowed to accumulate.     g) At Bldg. 94, South lunch room, underneath microwave, by window - On or about 2/16/12, lead dusts were allowed to accumulate.     h) At Bldg. 94, E-37 area adjacent to emergency shower, top of cabinet - On or about 2/16/12, lead dusts were allowed to accumulate.     i) At Bldg. 94, South mens locker room - On or about 2/16/12, lead dusts were allowed to accumulate.     j) At Bldg. 94, North lunch room, north side white refrigerator door handle - On or about 2/16/12, lead dusts were allowed to accumulate.    k) At Bldg. 94, North lunchroom, south side Gatorade dispenser - On or about 2/16/12, lead dusts were allowed to accumulate.     l) At Bldg. 94, North womens locker room - On or about 2/16/12, lead dusts were allowed to accumulate.     m) Bldg. 94, Hangar, Near column F-19, Top of electrical panel adjacent to 5-3-LP-1-02 - On or about 4/10/12, lead dusts were allowed to accumulate.     n) At Bldg. 94, Administration side, F/A-18 conference room, Return air vent - On or about 4/10/12, lead dusts were allowed to accumulate.     o) At Bldg. 94, Administration side, Supervisor's office, return air vent above kitchenette - On or about 4/10/12, lead dusts were allowed to accumulate.     p) At Bldg. 94, Mezzanine, Fencing adjacent to employee desk - On or about 4/10/12, lead dusts were allowed to accumulate.     q) At Bldg. 94, Mezzanine, Eyewash - On or about 4/10/12, lead dusts were allowed to accumulate.     r) At Bldg. 94, Mezzanine, Steel beam above break room area, adjacent to table - On or about 4/10/12, lead dusts were allowed to accumulate.     s) At Bldg. 94, Mezzanine, Break room, Top of locker - On or about 4/10/12, lead dusts were allowed to accumulate.     t) At Bldg. 94, Mezzanine, Break room, Steel beam above lockers - On or about 4/10/12, lead dusts were allowed to accumulate.     u) At Bldg. 94, Mezzanine, Top of red tool box - On or about 4/10/12, lead dusts were allowed to accumulate.     v) At Bldg. 94, Mezzanine, Break room, Refrigerator - On or about 4/10/12, lead dusts were allowed to accumulate.     w) At Bldg. 94, Mezzanine, Fencing above the Bonding shop - On or about 4/10/12, lead dusts were allowed to accumulate.     x) At Bldg. 94, First floor, Adjacent to stairs, Left of electrical panel L4.5 - On or about 4/10/12, lead dusts were allowed to accumulate.     y) At Bldg. 94, First floor, Engineering and Supervisor's office, top of cabinet - On or about 4/10/12, lead dusts were allowed to accumulate.     z) At Bldg. 94, First floor, Engineering and Supervisor's office, Fax machine - On or about 4/10/12, lead dusts were allowed to accumulate.     aa) At Bldg. 94, Mezzanine, Hallway ledge adjacent to fire extinguisher - On or about 4/10/12, lead dusts were allowed to accumulate.     ab) At Bldg. 94, Mezzanine, Hallway, Top of door frame - On or about 4/10/12, lead dusts were allowed to accumulate.     ac) At Bldg. 94, Contractor break room, top of refrigerator - On or about 4/10/12, lead dusts were allowed to accumulate.     ad) At Bldg. 94, E-37 floor below emergency shower - On or about 4/10/12, lead dusts were allowed to accumulate.     ae) At Bldg. 94, Middle quad desk, MSDS binder - On or about 4/10/12, lead dusts were allowed to accumulate.     af) At Bldg. 94, Middle quad desk, Employee clock out computer keyboard - On or about 4/10/12, lead dusts were allowed to accumulate.     Pursuant to 29 CFR 1903, the employer must submit documents describing the steps it is taking to ensure compliance, including a description of how this program will protect its employees from the hazards associated with lead.
Recent events (1)
  • · Z (S) $0

1910.1025 H02 II

Serious Gravity 10 1 instance 500 exposed
Issued
Aug 30, 2012
Abate by
Sep 26, 2012
Penalty
Initial $0 · Current $0

Hazardous substances 1591

29 CFR 1910.1025(h)(2)(ii): Shoveling, sweeping or brushing methods were used to remove lead accumulations where vacuuming or other equally effective methods were available and feasible:    a) At Bldg. 94 - On or about 4/10/12, and at times prior thereto, dry sweeping was performed throughout the hangar including the open bays of the center barrel area, disassembly area, Wing shop, Quickie shop, and mezzanine.    Pursuant to 29 CFR 1903, the employer must submit documents describing the steps it is taking to ensure compliance, including a description of how this program will protect its employees from the hazards associated with lead dusts.
Recent events (1)
  • · Z (S) $0

1960.8 A

Serious Gravity 10 1 instance 500 exposed
Issued
Aug 30, 2012
Abate by
Mar 31, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 0360

29 CFR 1960.8(a): The Agency head did not furnish employment and a place of employment to each employee that were free from recognized hazards that caused or were likely to cause death or serious physical harm to employees in that the employer failed to put into place Safety and Health programs, policies, and procedures to protect employees from the hazards of Beryllium.     Located in Bldg. 94, Hangar, Mezzanine, and Administration Offices, the employer failed to put into place Safety and Health programs, policies, and procedures to protect employees from the hazards of beryllium, which is likely to cause death and/or serious physical harm to employees.      AMONG OTHER METHODS, FEASIBLE AND ACCEPTABLE METHODS TO CORRECT THE HAZARD WOULD BE TO FOLLOW THE PROVISIONS OF:      ANSI standard is A37.29-1970 and DHHS (NIOSH Be Alert) Publication Number 2011 107 dated Feb. 2011 having feasible abatement methods for reducing this hazard include but are not limited to:   1. Institute a written effective Beryllium Dust and Exposure Control Program that details procedures for controlling beryllium dust contamination. The written program must indicate effective engineering controls, work practices, training, and housekeeping procedures.    2. Periodically evaluate the written program's effectiveness, including frequent and regular inspections by competent designated persons, HVAC balancing of the North Administration Offices, as well as institute changes when the written program is deemed ineffective.   3. Discontinue sanding and grinding in the open bays and conduct sanding and grinding operations in fully enclosed exhaust booths and isolation rooms that effectively capture all dusts generated by the operations.    4. Institute routine maintenance of ventilation engineering controls (vacuum tools, exhaust booths, etc.) to capture beryllium dusts generated during sanding and grinding operations.    5. Discontinue work practices of dry sweeping or other procedures that recirculate dusts into the air.    6. Institute effective use of vacuuming of work surfaces where dusts may have accumulated.    7. Require use of respirators and skin protective PPE to prevent exposure to beryllium dusts during work operations and clean up.    8. Require use of gloves while working in the zone of danger including desks and computer stations.    9. Evaluate and clean up dust accumulation throughout the building as well as the general HVAC system in the North Administration Office side of Bldg. 94.    10. Require employees to wash hands and faces before breaks and shower at the end of the work shift leaving at work site soiled work clothing or uniforms for laundering.    11. In Addition, USDOL-OSHA recommends the employer contact and request the National Institute for Occupational Safety and Health (NIOSH), to coordinate a Health Hazard Evaluation (HHE) study for beryllium. NIOSH a federal agency responsible for conducting research and making recommendations to prevent occupational illness and injury. NIOSH is part of the Centers for Disease Control and Prevention (CDC) in the Department of Health and Human Services (DHHS). The Health Hazard Evaluation (HHE) Program carries out the NIOSH mandate to respond to requests for investigations to learn whether exposures or conditions in specific workplaces pose a health hazard to workers.      Pursuant to 29 CFR 1903, the employer must submit documents describing the steps it is taking to ensure compliance, including a description of how this program will protect its employees from the hazards associated with beryllium dusts.
Recent events (1)
  • · Z (S) $0

1910.141 G02

Willful Gravity 10 13 instances 500 exposed
Issued
Aug 30, 2012
Abate by
Sep 26, 2012
Penalty
Initial $0 · Current $0

Hazardous substances 03601591C141

29 CFR 1910.141(g)(2): Employees were permitted to consume food or beverage in area(s) exposed to toxic materials:    a) At Bldg. 94, South lunch room, top of Dole juice dispenser - On or about 2/16/12, employees were permitted to consume food or beverages in areas exposed to cadmium.    b) At Bldg. 94, South lunch room, underneath microwave - On or about 2/16/12, employees were permitted to consume food or beverages in areas exposed to cadmium and lead.    c) At Bldg. 94, North lunch room, north side white refrigerator door handle - On or about 2/16/12, employees were permitted to consume food or beverages in areas exposed to cadmium and lead.    d) At Bldg. 94, North lunchroom, top of South side Gatorade dispenser - On or about 2/16/12, employees were permitted to consume food or beverages in areas exposed to cadmium and lead.    e) At Bldg. 94, Administration side, Supervisor's office kitchenette, box of Styrofoam cups - On or about 4/10/12, employees were permitted to consume food or beverages in areas exposed to cadmium.	     f) At Bldg. 94, Administration side, Supervisor's office kitchenette, return air vent above kitchenette - On or about 4/10/12, employees were permitted to consume food or beverages in areas exposed to cadmium and lead.	     g) At Bldg. 94, Mezzanine, Fencing adjacent to employee desk - On or about 4/10/12, employees were permitted to    consume food or beverages in areas exposed to cadmium and lead.    h) At Bldg. 94, Mezzanine, Steel beam above break room area, adjacent to table - On or about 4/10/12, employees were permitted to consume food or beverages in areas exposed to cadmium, lead, and beryllium.      i) At Bldg. 94, Mezzanine, Break room, Top of locker - On or about 4/10/12, employees were permitted to consume food or beverages in areas exposed to cadmium and lead.     j) At Bldg. 94, Mezzanine, Break room, Steel beam above lockers - On or about 4/10/12, employees were permitted to consume food or beverages in areas exposed to lead, cadmium, and beryllium.     k) At Bldg. 94, Mezzanine, Break room, Refrigerator - On or about 4/10/12, employees were permitted to consume food or beverages in areas exposed to cadmium and lead.     l) At Bldg. 94, Contractor room, refrigerator door handle - On or about 4/10/12, employees were permitted to consume food or beverages in areas exposed to cadmium.     m) At Bldg. 94, Contractor room, top of refrigerator - On or about 4/10/12, employees were permitted to consume food or beverages in areas exposed to cadmium and lead.     Pursuant to 29 CFR 1903, the employer must submit documents describing the steps it is taking to ensure compliance, including a description of how this program will protect its employees from the hazards associated with ingesting toxic materials.
Recent events (1)
  • · Z (W) $0

1910.141 G04

Willful Gravity 10 14 instances 500 exposed
Issued
Aug 30, 2012
Abate by
Sep 26, 2012
Penalty
Initial $0 · Current $0

Hazardous substances 03601591C141

29 CFR 1910.141(g)(4): Food or beverages were stored in area(s) exposed to toxic material(s):    a) At Bldg. 94, L-3C area, desk - On or about 2/16/12, food and beverages were stored in an area exposed to cadmium.    b) At Bldg. 94, South lunch room, top of Dole juice dispenser - On or about 2/16/12, food and beverages were stored in an area exposed to cadmium.    c) At Bldg. 94, South lunch room, underneath microwave - On or about 2/16/12, food and beverages were stored in an area exposed to cadmium and lead.    d) At Bldg. 94, North lunch room, north side white refrigerator door handle - On or about 2/16/12, food and beverages were stored in an area exposed to cadmium and lead.    e) At Bldg. 94, North lunchroom, top of South side Gatorade dispenser - On or about 2/16/12, food and beverages were stored in an area exposed to cadmium and lead.    f) At Bldg. 94, Administration side, Supervisor's office kitchenette, box of Styrofoam cups - On or about 4/10/12, food and beverages were stored in an area exposed to cadmium.	     g) At Bldg. 94, Administration side, Supervisor's office kitchenette, return air vent above kitchenette - On or about 4/10/12, food and beverages were stored in an area exposed to cadmium and lead.     h) At Bldg. 94, Mezzanine, Fencing adjacent to employee desk - On or about 4/10/12, food and beverages were stored in an area exposed to cadmium and lead.     i) At Bldg. 94, Mezzanine, Steel beam above break room area, adjacent to table - On or about 4/10/12, food and beverages were stored in an area exposed to lead, cadmium, and beryllium.     j) At Bldg. 94, Mezzanine, Break room, Top of locker - On or about 4/10/12, food and beverages were stored in an area exposed to lead and cadmium.     k) At Bldg. 94, Mezzanine, Break room, Steel beam above lockers - On or about 4/10/12, food and beverages were stored in an area exposed to lead, cadmium, and beryllium.     l) At Bldg. 94, Mezzanine, Break room, Refrigerator - On or about 4/10/12, food and beverages were stored in an area exposed to lead and cadmium.    m) At Bldg. 94, Contractor break room, Refrigerator door handle - On or about 4/10/12, food and beverages were stored in an area exposed to cadmium.     n) At Bldg. 94, Contractor break room, top of refrigerator - On or about 4/10/12, food and beverages were stored in an area exposed to lead and cadmium.     Pursuant to 29 CFR 1903, the employer must submit documents describing the steps it is taking to ensure compliance, including a description of how this program will protect its employees from the hazards associated with ingesting toxic materials.
Recent events (1)
  • · Z (W) $0

1910.1027 K01

Willful Gravity 10 37 instances 500 exposed
Issued
Aug 30, 2012
Abate by
Dec 31, 2013
Penalty
Initial $0 · Current $0

Hazardous substances C141

29 CFR 1910.1027(k)(1): Surfaces were not maintained as free as practicable of accumulations of cadmium:    a) At Bldg. 94, Quickie shop, top of Dustron grind booth 039809 - On or about 2/16/12, cadmium dusts were allowed to accumulate.     b) At Bldg. 94, Quickie shop, top of panel of Dustron 039809 grind booth - On or about 2/16/12, cadmium dusts were allowed to accumulate.    c) At Bldg. 94, Wing Shop, Dustron grind booth floor - On or about 2/16/12, cadmium dusts were allowed to accumulate.     d) At Bldg. 94, Wing shop, top of black metal cabinet - On or about 2/16/12, cadmium dusts were allowed to accumulate.     e) At Bldg. 94, Bldg. 94, Wing shop, cart - On or about 2/16/12, cadmium dusts were allowed to accumulate.     f) At Bldg. 94, South lunch room, top of Dole juice dispenser - On or about 2/16/12, cadmium dusts were allowed to accumulate.     g) At Bldg. 94, South lunch room, underneath microwave, by window - On or about 2/16/12, cadmium dusts were allowed to accumulate.     h) At Bldg. 94, E-37 area adjacent to emergency shower, top of cabinet - On or about 2/16/12, cadmium dusts were allowed to accumulate.     i) At Bldg. 94, South mens locker room - On or about 2/16/12, cadmium dusts were allowed to accumulate.     j) At Bldg. 94, North lunch room, north side white refrigerator door handle - On or about 2/16/12, cadmium dusts were allowed to accumulate.    k) At Bldg. 94, North lunchroom, south side Gatorade dispenser - On or about 2/16/12, cadmium dusts were allowed to accumulate.     l) At Bldg. 94, North womens locker room - On or about 2/16/12, cadmium dusts were allowed to accumulate.     m) At Bldg. 94, Hangar, Near column F-19, Top of electrical panel adjacent to 5-3-LP-1-02 - On or about 4/10/12, cadmium dusts were allowed to accumulate.     n) At Bldg. 94, Administration side, Airspeed training room, computer station, keyboard - On or about 4/10/12, cadmium dusts were allowed to accumulate.     o) At Bldg. 94, Administration side, F/A-18 conference room, Return air vent - On or about 4/10/12, cadmium dusts were allowed to accumulate.     p) At Bldg. 94, Administration side, Supervisor's office kitchenette, box of styrofoam cups - On or about 4/10/12, cadmium dusts were allowed to accumulate.     q) At Bldg. 94, Administration side, Supervisor's office, return air vent above kitchenette - On or about 4/10/12, cadmium dusts were allowed to accumulate.     r) At Bldg. 94, Administration side, Men's restroom, Return air vent - On or about 4/10/12, cadmium dusts were allowed to accumulate.     s) At Bldg. 94, Administration side, Women's restroom, Return air vent - On or about 4/10/12, cadmium dusts were allowed to accumulate.     t) At Bldg. 94, Mezzanine, Fencing adjacent to employee desk - On or about 4/10/12, cadmium dusts were allowed to accumulate.     u) At Bldg. 94, Mezzanine, Eyewash - On or about 4/10/12, cadmium dusts were allowed to accumulate.     v) At Bldg. 94, Mezzanine, Steel beam above break room area, adjacent to table - On or about 4/10/12, cadmium dusts were allowed to accumulate.     w) At Bldg. 94, Mezzanine, Break room, Top of locker - On or about 4/10/12, cadmium dusts were allowed to accumulate.     x) At Bldg. 94, Mezzanine, Break room, Steel beam above lockers - On or about 4/10/12, cadmium dusts were allowed to accumulate.     y) At Bldg. 94, Mezzanine, Top of red tool box - On or about 4/10/12, cadmium dusts were allowed to accumulate.     z) At Bldg. 94, Mezzanine, Break room, Refrigerator - On or about 4/10/12, cadmium dusts were allowed to accumulate.     aa) At Bldg. 94, Mezzanine, Fencing above the Bonding shop - On or about 4/10/12, cadmium dusts were allowed to accumulate.     ab) At Bldg. 94, First floor, Adjacent to stairs, Left of electrical panel L4.5 - On or about 4/10/12, cadmium dusts were allowed to accumulate.     ac) At Bldg. 94, First floor, Engineering and Supervisor's office, top of cabinet - On or about 4/10/12, cadmium dusts were allowed to accumulate.     ad) At Bldg. 94, First floor, Engineering and Supervisor's office, Fax machine - On or about 4/10/12, cadmium dusts were allowed to accumulate.     ae) At Bldg. 94, Mezzanine, Hallway ledge adjacent to fire extinguisher - On or about 4/10/12, cadmium dusts were allowed to accumulate.     af) At Bldg. 94, Mezzanine, Hallway, Top of door frame - On or about 4/10/12, cadmium dusts were allowed to accumulate.     ag) At Bldg. 94, Contractor break room, refrigerator door handle - On or about 4/10/12, cadmium dusts were allowed to accumulate.     ah) At Bldg. 94, Contractor break room, top of refrigerator - On or about 4/10/12, cadmium dusts were allowed to accumulate.     ai) At Bldg. 94, E-37 floor below emergency shower - On or about 4/10/12, cadmium dusts were allowed to accumulate.     aj) At Bldg. 94, Middle quad desk, MSDS binder - On or about 4/10/12, cadmium dusts were allowed to accumulate.     ak) At Bldg. 94, Middle quad desk, Employee clock out computer keyboard - On or about 4/10/12, cadmium dusts were allowed to accumulate.      Pursuant to 29 CFR 1903, the employer must submit documents describing the steps it is taking to ensure compliance, including a description of how this program will protect its employees from the hazards associated with cadmium dusts.
Recent events (1)
  • · Z (W) $0

1910.1027 K05

Willful Gravity 10 1 instance 500 exposed
Issued
Aug 30, 2012
Abate by
Sep 26, 2012
Penalty
Initial $0 · Current $0

Hazardous substances C141

29 CFR 1910.1027(k)(5): Shoveling, dry or wet sweeping and brushing were used where vacuuming or other methods that minimize the likelihood of cadmium becoming airborne had not been tried and/or had been found effective:    a) At Bldg. 94 - On or about 4/10/12, and at times prior thereto, dry sweeping was performed throughout the hangar including the open bays of the center barrel area, disassembly area, Wing shop, Quickie shop, mezzanine, and lunch rooms.    Pursuant to 29 CFR 1903, the employer must submit documents describing the steps it is taking to ensure compliance, including a description of how this program will protect its employees from the hazards associated with beryllium dusts.
Recent events (1)
  • · Z (W) $0

View Fleet Readiness Center's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 332836998.