OSHA Inspection: TURBONETICS ENGINEERING & SERVICES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TURBONETICS ENGINEERING & SERVICES, INC. in 1845 N. LEXINGTON BLVD., CORPUS CHRISTI, TX 78409 (NAICS 332710). OSHA activity number 333291425.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Turbonetics Engineering & Services, INC. for free Get an email when a new federal OSHA severe-injury report for Turbonetics Engineering & Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1845 N. LEXINGTON BLVD.
City
CORPUS CHRISTI
State
TX
ZIP
78409
Mailing
1845 N. LEXINGTON BLVD., CORPUS CHRISTI, TX 78409
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
30
Ownership type
A

6 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 12 exposed
Issued
Sep 26, 2012
Abate by
Oct 18, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.22(a)(1):     All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.    At this workplace, work areas and floors were littered with metal shavings, oil spills, dirty rags and rubbish exposing employees to slip and fall hazards.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.147 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 26, 2012
Abate by
Nov 30, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.147(c)(1):     The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:      At this workplace employees conducting repairs and maintenance on shop machinery such as but not limited to R.K LeBlond Model TL-660b did not have a hazardous energy program in place.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.212 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 26, 2012
Abate by
Nov 30, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    At this workplace employees operate shop machinery such as but not limited to R.K LeBlond TL-660B without protection from mechanical motion or flying objects.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.212 B

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 26, 2012
Abate by
Nov 30, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.212(b):     Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:      At this workplace employees operate shop machinery such as but not limited to R.K LeBlond Model TL-660b was not securely anchored to the floor.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800

1910.253 B04 III

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Sep 26, 2012
Abate by
Oct 18, 2012
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.253(b)(4)(iii):     Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least    At this workplace in the rear yard of the facility oxygen and acetylene cylinders are stored immediately next to one another without a barrier in place.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3500

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 26, 2012
Abate by
Oct 18, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    At this workplace employees utilize shop bench grinders energized by a job made electrical cord for approximately 5 years.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2800