MONTGOMERYVILLE, PA —
OSHA Inspection: PENN MANUFACTURING INDUSTRIES, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of PENN MANUFACTURING INDUSTRIES, INC. in 506 STUMP ROAD, MONTGOMERYVILLE, PA 18936 (NAICS 332710). OSHA activity number 333292761.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PENN MANUFACTURING INDUSTRIES, INC.
- Site address
- 506 STUMP ROAD
- City
- MONTGOMERYVILLE
- State
- PA
- ZIP
- 18936
- Mailing
- 506 STUMP RD., MONTGOMERYVILLE, PA 18936
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 80
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.125 A
- Issued
- May 21, 2012
- Abate by
- Jun 5, 2012
- Penalty
- Initial $3,060 · Current $2,142 Reduced
General-duty citation text
29 CFR 1910.125(a): Dip tank were not made of noncombustible material: a. Tumbling/Abrasive Blasting Area - On or about 4/10/12, containers are being used by employees as dip tanks to clean parts with a flammable liquid (acetone), as well as to store the acetone overnight. These containers did not meet the requirements of an approved container for storage of flammable liquids. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2142
- — Z (S) $3060
1910.125 E02
- Issued
- May 21, 2012
- Abate by
- Jun 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.125(e)(2): Portable container(s) used to add liquid to the tank were not electrically bonded to the dip tank and positively grounded to prevent static electrical sparks or arcs: a. Tumbling/Abrasive Blasting Area - On or about 4/10/12, Employees filling a Buckhorn Plastic container, used for degreasing, with a one gallon metal container of Sherwin Williams Acetone and did not bond or ground the container to eliminate the potential for static sparks. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.151 C
- Issued
- May 21, 2012
- Abate by
- Jun 20, 2012
- Penalty
- Initial $3,060 · Current $2,142 Reduced
2310
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a. Manufacturing Area - On or about 3/28/12, The employer did not provide the employee with an eye wash which provided water for both eyes and the ability to flush skin for 15 minutes, in the immediate area where the GNB battery for the Toyota fork lift was checked or filled with electrolyte or water. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement
Recent events (2)
- — I (S) $2142
- — Z (S) $3060
1910.1200 F05 II
- Issued
- May 21, 2012
- Abate by
- May 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: a. Tumbling/Abrasive Blasting Area - On or about 4/10/12, A Buckhorn attached lid container was being used by employees as a dip tank with Sherwin Williams R6K9 acetone was not labeled with the hazard warning. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Penn Manufacturing Industries, INC.
View Penn Manufacturing Industries, INC.'s full OSHA safety record →