Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PENN MANUFACTURING INDUSTRIES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PENN MANUFACTURING INDUSTRIES, INC. in 506 STUMP ROAD, MONTGOMERYVILLE, PA 18936 (NAICS 332710). OSHA activity number 333294320.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Penn Manufacturing Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Penn Manufacturing Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
506 STUMP ROAD
City
MONTGOMERYVILLE
State
PA
ZIP
18936
Mailing
506 STUMP ROAD, MONTGOMERYVILLE, PA 18936
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
80
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
May 21, 2012
Abate by
Jun 20, 2012
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i):     Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:            a)  Throughout Facility - Employees doing maintenance on various machines such as the Tumbler and there were no written procedures developed on or about 3/28/12.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3500

1910.147 C05 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
May 21, 2012
Abate by
Jun 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(i):     Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:        a)  Throughout Facility - Employees doing maintenance on various machines such as the tumbler and not using locks to lock them out on or about 3/28/12.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F01

Other-than-serious 1 instance 1 exposed
Issued
May 21, 2012
Abate by
Jun 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(1):     Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:      a)  Assembly Area - The panel box was not labeled to identify each circuit breakers function on or about 3/28/12.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Penn Manufacturing Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333294320.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.