ORANGEBURG, NY —
OSHA Inspection: AVERY DENNISON INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of AVERY DENNISON INC. in 524 ROUTE 303, ORANGEBURG, NY 10962 (NAICS 313320). OSHA activity number 333294494.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AVERY DENNISON INC.
- Site address
- 524 ROUTE 303
- City
- ORANGEBURG
- State
- NY
- ZIP
- 10962
- Mailing
- 524 ROUTE 303, ORANGEBURG, NY 10962
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 313320
- Employees
- 38
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.106 E06 I
- Issued
- Aug 1, 2012
- Abate by
- Aug 31, 2012
- Penalty
- Initial $4,000 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors: a) Viscosity Testing Table: A viscometer used to measure the viscocity of flammable liquids was not designed for flammable liquid usage; on or about 5/18/12. b) Coating Line C: Flammable liquids fell from troughs through the air and into open pails. The troughs and the pails were not electrically interconnected; on or about 5/18/12.
Recent events (2)
- — I (S) $2800
- — Z (S) $4000
1910.106 E06 II
- Issued
- Aug 1, 2012
- Abate by
- Aug 16, 2012
- Penalty
- Initial $4,000 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I liquids were dispensed into containers without the nozzle and container electrically interconnected: a) Mixing Room: Solvents including isopropyl alcohol, toluene and methyl ethyl ketone were pumped from underground storage tanks to portable tanks and the fill pipes were not electrically interconnected; on or about 5/18/12. b) Mixing Room: Flammable coating chemicals including M70 (toluene, ispropyl alcohol) M71 (toluene, isopropyl alcohol) and 8125 (methyl ethyl ketone, toluene) were pumped from indoor above ground storage tanks to portable tanks and the fill pipes were not electrically interconnected to the portable tanks; on or about 5/18/12. c) Mixing Room: K7800 White Topcoat (toluene, isopropyl alcohol) was pumped from a tote tank to a portable tank and the fill pipe was not electrically interconnected to the portable tank; on or about 5/18/12. d) Pump Room: A flammable coating chemical (toluene, isopropyl alcohol) was being drained from an outlet pipe of a tote tank into an open pail without them being electrically interconnected; on or about 5/21/12.
Recent events (2)
- — I (S) $2800
- — Z (S) $4000
1910.106 E09 III
- Issued
- Aug 1, 2012
- Abate by
- Aug 11, 2012
- Penalty
- Initial $4,000 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: a) Cleaning Room - Blade Cleaning Operation: Rags and waste coated with Zinsser Spray-On Stripper (combustible) were not stored in covered metal receptacles; on or about 2/27/12.
Recent events (2)
- — I (S) $2800
- — Z (S) $4000
1910.106 H04 IV
- Issued
- Aug 1, 2012
- Abate by
- Aug 31, 2012
- Penalty
- Initial $4,000 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.106(h)(4)(iv): Equipment was not designed to prevent the unintentional escape of liquids and vapors to minimize the quantity escaping in the event of an accidental release: a) Mixing Room - Filling of Portable Tanks from Indoor Storage Tanks: Fill Lines being used to fill portable tanks with the flammable liquid compounds (M70, 8125 and M71) did not have self-closing valves; on or about 5/18/12.
Recent events (2)
- — I (S) $2800
- — Z (S) $4000
1910.160 B06
- Issued
- Aug 1, 2012
- Penalty
- Initial $4,000 · Current $2,800 Reduced
General-duty citation text
29 CFR 1910.160(b)(6): Fixed extinguishing systems were not inspected annually by a person knowledgeable in the design and function of the system to assure that the system is maintained in good operating condition: a) Coating Line C: The fixed extinguishing system was not inspected annually; on or about 5/21/12.
Recent events (2)
- — I (S) $2800
- — Z (S) $4000
1910.160 B07
- Issued
- Aug 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.160(b)(7): The weight and pressure of refillable containers of fixed extinguishing systems were not checked at least semi-annually: a) Coating Line C: The weight and pressure of refilable containers of the fixed extinguisher system were not check at least semi-annually; on or about 5/21/12.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 M02
- Issued
- Aug 1, 2012
- Abate by
- Aug 11, 2012
- Penalty
- Initial $5,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.178(m)(2): No person shall be allowed to stand or pass under the elevated portion of any truck, whether loaded or empty: a) Pump Room: An employee worked under a tote tank being elevated by a forklift truck; on or about 5/21/12.
Recent events (2)
- — I (S) $3500
- — Z (S) $5000
1910.1052 L03 I
- Issued
- Aug 1, 2012
- Penalty
- Initial $4,000 · Current $2,800 Reduced
1730
General-duty citation text
29 CFR 1910.1052(l)(3)(i): The employer did not inform each affected employee of the requirements of 29 CFR 1910.1052 and the information available in its appendices and how to access or obtain a copy of it in the workplace a) Cleaning Room - Blade Cleaning Operation: Employees cleaned blades using Zissner Spray-On Stripper (methylene chloride) and the employer did not provide information required by the standard; on or about 2/27/12.
Recent events (2)
- — I (S) $2800
- — Z (S) $4000
1910.1200 H03 II
- Issued
- Aug 1, 2012
- Penalty
- Initial $0 · Current $0
1730
General-duty citation text
29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area: a) Cleaning Room - Blade Cleaning Operation: Employees cleaned blades using Zissner Spray-On Stripper (methylene chloride) and the employer provide training on the physical and health hazards of this chemical; on or about 2/27/12.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H03 I A
- Issued
- Aug 1, 2012
- Abate by
- Aug 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(3)(i)(A): Respirators used in routine situations were not inspected before each use and during cleaning: a) Blade Cleaning Room/Coating Line - For protection against methylene chloride and solvent vapors (e.g., toluene, isopropyl alcohol, methyl ethyl ketone), an employee wore a half-mask respirator that was missing an inhalation valve. The employer did not ensure that this respirator was inspected before each use; on or about 2/27/12. b) Mixing Room: For protection against solvent vapors (e.g., toluene, isopropyl alcohol, methyl ethyl ketone), an employee wore a full-face respirator that was missing an inhalation valve. The employer did not ensure that this respirator was inspected before each use; on or about 4/12/12.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1052 D02
- Issued
- Aug 1, 2012
- Penalty
- Initial $0 · Current $0
1730
General-duty citation text
29 CFR 1910.1052(d)(2): The employer did not perform initial monitoring to determine each employee's exposure to methylene chloride: a) Cleaning Room - Blade Cleaning Operation: Employees cleaned blades using chemical x (methylene chloride) and the employer did not perform initial monitoring to determine employee exposure to methylene chloride; on or about 2/27/12.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Avery Dennison INC.
View Avery Dennison INC.'s full OSHA safety record →
More inspections in this industry (NAICS 313320)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333294494.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.