Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AVERY DENNISON INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of AVERY DENNISON INC. in 524 ROUTE 303, ORANGEBURG, NY 10962 (NAICS 313320). OSHA activity number 340514876.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Avery Dennison INC. — free Get an email when a new federal OSHA severe-injury report for Avery Dennison INC. is published. One employer, no account, unsubscribe in one click.
Establishment
AVERY DENNISON INC.
Site address
524 ROUTE 303
City
ORANGEBURG
State
NY
ZIP
10962
Mailing
524 ROUTE 303, ORANGEBURG, NY 10962
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
313320
Employees
28
Ownership type
A

6 citations on file for this inspection.

1910.106 E06 II

Serious Gravity 5 3 instances 2 exposed
Issued
Sep 22, 2015
Abate by
Oct 9, 2015
Penalty
Initial $4,000 · Current $2,600 Reduced
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were dispensed into containers without the nozzle and container being electrically interconnected:    a) Mixing Room:  An employee dispensed a flammable solvent (methyl ethyl ketone) from the main methyl ethyl ketone solvent line into a 5-gallon pail without the nozzle and the container being electrically interconnected; on or about 4/13/15.    b) Mixing Room:  An employee dispensed flammable resin (dimethylformamide) from 3 drums into a mixing tank without the drums and the mixing tank being electrically interconnected; on or about 6/18/15.    c) Mixing Room:  An employee dispensed flammable solvents (toluene and isopropyl alcohol) from the main solvent lines into a 5-gallon pail without the nozzle and the container being electrically interconnected; on or about 6/18/15.
Recent events (2)
  • — I (S) $2600
  • — Z (S) $4000

1910.133 A01

Serious Gravity 1 2 instances 2 exposed
Issued
Sep 22, 2015
Abate by
Oct 9, 2015
Penalty
Initial $3,000 · Current $1,950 Reduced
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:    a)  Coating Line (C) - Inside Coating Head Stations:   Employees changing drums, totes and inspecting and adjusting coating related equipment during the pumping and application of solvent-based coatings (toluene, methyl ethyl ketone, dimethylformamide, etc.) onto fabric and were not required to wear appropriate eye protection (e.g., chemical splash goggles or equivalent); on or about 3/25/15.    b) Coating Line (C) - Inside Coating Head Stations:   Employees changing drums, totes and inspecting and adjusting coating related equipment during the pumping and application of solvent-based coatings (toluene, methyl ethyl ketone, etc.) onto fabric and were not required to wear appropriate eye protection (e.g., chemical splash goggles or equivalent); on or about 6/18/15.
Recent events (2)
  • — I (S) $1950
  • — Z (S) $3000

1910.138 A

Serious Gravity 1 3 instances 3 exposed
Issued
Sep 22, 2015
Abate by
Oct 9, 2015
Penalty
Initial $3,000 · Current $1,950 Reduced
29 CFR 1910.138(a): The employer did not require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes:    a) Coating Line (C):  An employee moved equipment inside the coating head station (e.g., pump, tote tank, drums, etc.) that had solvent-based coating residue on them (e.g., toluene, dimethylformamide) and was not required to wear chemical-resistant gloves; on or about 4/13/15.    b) Mixing Room - An employee handled equipment (e.g., tote tanks, bonding wires, etc.) that was coated with residue from solvent based coatings (toluene, dimethylformamide),  and was not required to wear chemical-resistant gloves; on or about 4/13/15.    c) Coating Line (C) - An employee handled equipment (e.g., pump, tote tank, etc.) inside the coating head station that had a solvent-based coating residue on it (toluene, dimethylformamide) and was not required to wear chemical-resistant gloves; on or about 6/18/15.
Recent events (2)
  • — I (S) $1950
  • — Z (S) $3000

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 22, 2015
Abate by
Oct 9, 2015
Penalty
Initial $5,000 · Current $3,180 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    a)  Main Production Area - Near Coating Line (C):   A circuit breaker box was missing a breaker, resulting in the live buss bar being exposed; on or about 6/18/15.
Recent events (2)
  • — I (S) $3180
  • — Z (S) $5000

1910.134 H03 I A

Repeat 1 instance 3 exposed
Issued
Sep 22, 2015
Penalty
Initial $200 · Current $200

Hazardous substances 0930

29 CFR 1910.134(h)(3)(i)(A): Respirators used in routine situations were not inspected before each use:  a)  Coating Line and Mixing Room Areas:  Employees mixing solvents (toluene, methyl ethyl ketone, dimethylformamide, etc.) and entering coating head stations used half-face and full-face air purifying respirators that were missing inhalation valves and the respirators were not inspected before each use;  on or about 3/25/15.   Avery Dennison Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard [ 29 CFR 1910.134(h)(3)(i)(A) ] which was contained in OSHA inspection number 329449, citation number 2, item number 1 and was affirmed as a final order on August 23, 2012, with respect to a workplace located at 524 Route 303, Orangeburg, NY 10962.
Recent events (2)
  • — I (R) $200
  • — Z (R) $200

1910.134 G01 I B

Other-than-serious 3 instances 4 exposed
Issued
Sep 22, 2015
Abate by
Oct 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(g)(1)(i)(B): Respirators with tight-fitting facepieces were worn by employees with a condition that interfered with the face-to-facepiece seal or valve function:  a) C-Line Coating Operation:  An employee using solvent based coatings to perform coating operations wore a half-face air purifying respirator with a hat between the respirator straps and his head; on or about 4/13/15.  b)  Mixing Room:  Employees blending raw materials (e.g., various solvents and solvent-based chemicals) to make coatings wore full-face air purifying respirators with the hoods of the full body disposable suits between the respirator straps and their heads; on or about 4/13/15.  c)  Mixing Room:  Employees blending raw materials (e.g., various solvents and solvent-based chemicals) to make coatings wore full-face air purifying respirators with the hoods of the full body disposable suits between the respirator straps and their heads; on or about 6/18/15.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Avery Dennison INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340514876.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.