MAPLE PARK, IL —
OSHA Inspection: CARDINAL INDUSTRIES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CARDINAL INDUSTRIES, INC. in 5N200 WOOLEY RD, MAPLE PARK, IL 60151 (NAICS 321211). OSHA activity number 333296945.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CARDINAL INDUSTRIES, INC.
- Site address
- 5N200 WOOLEY RD
- City
- MAPLE PARK
- State
- IL
- ZIP
- 60151
- Mailing
- 5N200 WOOLEY RD, MAPLE PARK, IL 60151
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321211
- Employees
- 15
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C01
- Issued
- Aug 27, 2012
- Abate by
- Sep 26, 2012
- Penalty
- Initial $2,800 · Current $1,120 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energization, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: Entire Facility. The employer did not have an established lockout/tagout program for employees who performed servicing and maintenance on machines and equipment such as but not limited to saws, CNC routers, perforators, laminator and dust collectors (auger cleanout). Abatement Note: A lockout/tagout program should include the following key elements: - Energy source evaluation - Development, documentation and utilization of machine-specific procedures - Procedures for group lockout (when more than one employee is servicing the same equipment at the same time) - Training for "authorized," "affected," and "other" employees - Periodic inspections (at least annual) - Sharing of lockout/tagout program information with outside contractors Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $1120
- — Z (S) $2800
1910.213 H01
- Issued
- Aug 27, 2012
- Penalty
- Initial $2,000 · Current $800 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the stock being cut to give maximum protection possible for the operation being performed. (a) Shipping and Receiving. The Pro-Tech radial chop saw did not have a self-adjusting guard covering the exposed lower portion of the blade. There is no abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $800
- — Z (S) $2000
1910.213 H04
- Issued
- Aug 27, 2012
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.213(h)(4): Radial Saw was not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator: (a) Shipping and Receiving. The cutting head of the Delta Radial Saw did not return to the starting position when released by the operator. There is no abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1910.303 G01
- Issued
- Aug 27, 2012
- Penalty
- Initial $1,020 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment (a) Wall adjacent to Compressor Room. Access to the electrical shutoffs for the generators for air compressors was obstructed by a large compressor. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $1020
1910.303 G02 I
- Issued
- Aug 27, 2012
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i). a) Shipping and Receiving. An electrical junction box on the wall was missing a cover, exposing energized conductors inside (110-120V). There is no abatament certification or documentation required for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $1200
1910.178 L06
- Issued
- Aug 27, 2012
- Abate by
- Sep 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l). (a) The employer did not certify that all employees authorized to operate powered industrial trucks had received training and a performance evaluation at least once every three years. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.219 F03
- Issued
- Aug 27, 2012
- Abate by
- Sep 26, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed. (a) Laminating Machine. A chain and sprocket on a motor on the side of the machine was not guarded, creating potential employee exposure to the ingoing nip point. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Cardinal Industries, INC.
View Cardinal Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321211)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333296945.