MALONE, NY ·
OSHA Inspection: DANKO CONSTRUCTION CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DANKO CONSTRUCTION CORPORATION in CEREBRAL PALSY CENTER, COUNTY HIGHWAY 51, MALONE, NY 12953 (NAICS 236220). OSHA activity number 333297471.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DANKO CONSTRUCTION CORPORATION
- Site address
- CEREBRAL PALSY CENTER, COUNTY HIGHWAY 51
- City
- MALONE
- State
- NY
- ZIP
- 12953
- Mailing
- STATE ROUTE #56 P.O. BOX 239, MASSENA, NY 13662
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 9
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1926.153 L
- Issued
- Apr 17, 2012
- Penalty
- Initial $3,300 · Current $1,650 Reduced
General-duty citation text
29 CFR 1926.153(l): LP-Gas storage locations were not provided with at least one approved portable fire extinguisher having a rating of not less than 20-B:C: a) East side of building, exterior, on or about 3-29-12: Employees were using a 1000 gallon Liquefied Petroleum Gas (LPG) tank for building heat with no fire extinguisher in the area.
Recent events (3)
- · J (S) $1650
- · C (S) $3300
- · Z (S) $3300
1926.153 O
- Issued
- Apr 17, 2012
- Abate by
- Apr 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.153(o): When damage to LP-Gas systems from vehicular traffic was a possibility, precautions against such damage were not taken: a) East side of building, exterior, on or about 3-29-12: Employees were operating equipment immediately adjacent to a 1000 gallon Liquefied Petroleum Gas (LPG) tank that was not protected against accidental contact. Abatement certification is required for this item.
Recent events (3)
- · J (S) $0
- · C (S) $0
- · Z (S) $0
1926.304 F
- Issued
- Apr 17, 2012
- Abate by
- Apr 27, 2012
- Penalty
- Initial $3,300 · Current $1,650 Reduced
General-duty citation text
29 CFR 1926.304(f): Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: Section 5.1.3.3 American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure: a) First floor of building, east end, on or about 3-29-12: Employees were ripping framing lumber on a table saw that was not equipped with a spreader. b) First floor of building, north end, on or about 3-29-12: Employees were ripping framing lumber on a table saw that was not equipped with non kick-back fingers or dogs. c) First floor of building, north end, on or about 3-29-12: Employees were operating a table saw that was not equipped with a magnetic switch or anti-restart device. Abatement certification is required for this item.
Recent events (3)
- · J (S) $1650
- · C (S) $3300
- · Z (S) $3300
1926.304 I01
- Issued
- Apr 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.304(i)(1): Each circular hand-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: a) East end of building, interior, on or about 3-29-12: Employees were ripping framing lumber on a table saw that was not equipped with a hood guard that automatically adjusts to enclose the saw blade.
Recent events (3)
- · J (S) $0
- · C (S) $0
- · Z (S) $0
1926.304 G01
- Issued
- Apr 17, 2012
- Penalty
- Initial $4,620 · Current $2,310 Reduced
General-duty citation text
29 CFR 1926.304(g)(1): The sides of the lower exposed portion of the blade were not guarded to the full diameter of the blade by a device that would automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed: a) Center of building, on or about 3-29-12: One employee was operating a radial arm saw that was not equipped with a guard protecting the lower half of the blade.
Recent events (3)
- · J (S) $2310
- · C (S) $4620
- · Z (S) $4620
1926.404 B01 II
- Issued
- Apr 17, 2012
- Penalty
- Initial $3,300 · Current $1,650 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection: a) East wall of building, interior, on or about 3-29-12: Employees were operating multiple power tools, powered through a temporary power panel that was not protected by a ground fault circuit interrupter (GFCI).
Recent events (3)
- · J (S) $1650
- · C (S) $3300
- · Z (S) $3300
1926.1052 C01 II
- Issued
- Apr 17, 2012
- Penalty
- Initial $2,640 · Current $1,320 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever was less, were not equipped with one stairrail system along each unprotected side or edge: a) First floor, east end of building, on or about 3-29-12: Employees were using a stairway without a stair rail system along each of the unprotected sides.
Recent events (3)
- · J (S) $1320
- · C (S) $2640
- · Z (S) $2640
More inspections at Danko Construction Corporation
View Danko Construction Corporation's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 333297471.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.