LENORAH, TX —
OSHA Inspection: ACME ENERGY SERVICES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ACME ENERGY SERVICES, INC. in RIG #30, GIBSON '9' LEASE, WELL #3, 3.8 MILES SOUTH OF LENORAH, LENORAH, TX 79749 (NAICS 213111). OSHA activity number 333885051.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACME ENERGY SERVICES, INC.
- Site address
- RIG #30, GIBSON '9' LEASE, WELL #3, 3.8 MILES SOUTH OF LENORAH
- City
- LENORAH
- State
- TX
- ZIP
- 79749
- Mailing
- 7500 W HIGHWAY 80, MIDLAND, TX 79706
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.22 B01
- Issued
- Jul 16, 2012
- Abate by
- Jul 17, 2012
- Penalty
- Initial $3,825 · Current $0 Reduced
General-duty citation text
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear, with no obstruction across or in aisles that could create a hazard. At Rig #30, on or about April 10, 2012, at the top of the stairway leading up to the rig floor, an air hose laid across the entire width of stairway causing a trip/fall hazard. Exposed to trip/fall hazard of 29-feet to the ground were six employees working on and around the rig floor.
Recent events (3)
- — J (S) $0
- — C (S) $3825
- — Z (S) $3825
1910.305 G02 III
- Issued
- Jul 16, 2012
- Abate by
- Jul 17, 2012
- Penalty
- Initial $2,295 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: Rig #30: On or about April 10, 2012, a 400 watt Appleton Area Master Flood Light attached to light pole #20 at the Shaker Area showed signs of damage. Employee(s) were exposed to a potential electrical shock hazards due to the following instances: a. The strain relief/insulation that prevents conductors from directly transmitting to joints or terminal screws had pulled apart 4 to 6 inches from the device. b. The exposed white conductor had a cut in its insulation.
Recent events (3)
- — J (S) $0
- — C (S) $2295
- — Z (S) $2295
More inspections at Acme Energy Services, INC.