EAU CLAIRE, WI ·
OSHA Inspection: SOUTH GATE ROOFING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SOUTH GATE ROOFING, LLC in 2405 HENRY AVENUE, EAU CLAIRE, WI 54701 (NAICS 238160). OSHA activity number 333886422.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOUTH GATE ROOFING, LLC
- Site address
- 2405 HENRY AVENUE
- City
- EAU CLAIRE
- State
- WI
- ZIP
- 54701
- Mailing
- 2621 FAIRFAX STREET, EAU CLAIRE, WI 54701
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- May 7, 2012
- Penalty
- Initial $1,020 · Current $1,020
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b) Note: If using these systems was infeasible or created a greater hazard, the employer should develop and implement a fall protection plan meeting the requirements of paragraph (k) of 1926.502. (a) Residential reroofing project at 2405 Henry Street in Eau Claire, WI; Fall protection systems were not installed and/or used during reroofing operations on a residential home where the slope was approximately 5 in 12 and the eaves height was 9.6 feet.
Recent events (1)
- · Z (S) $1020
1926.1051 A
- Issued
- May 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: (a) Reroofing site located at 2405 Henry Street, Eau Claire, WI; A ladder or ramp was not installed so as, to permit employees to exit the roof. The eaves hight was 9.6 feet above the lower level.
Recent events (1)
- · Z (O) $0
More inspections at South Gate Roofing, LLC
View South Gate Roofing, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333886422.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.