Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SMC METAL FABRICATORS INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SMC METAL FABRICATORS INC in 2100 S OAKWOOD RD, OSHKOSH, WI 54904 (NAICS 332999). OSHA activity number 333924306.

Watch SMC Metal Fabricators INC — free Get an email when a new federal OSHA severe-injury report for SMC Metal Fabricators INC is published. One employer, no account, unsubscribe in one click.
Site address
2100 S OAKWOOD RD
City
OSHKOSH
State
WI
ZIP
54904
Mailing
2100 SO. OAKWOOD ROAD, OSHKOSH, WI 54904
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
92
Ownership type
A

3 citations on file for this inspection.

1910.217 B07 V C

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $2678.00 · Current $1875.00 Reduced
29 CFR 1910.217(b)(7)(v)(c): The two hand control system of mechanical power press(es) using part revolution clutches did not incorporate an antirepeat feature:    a) The SBL South Bend Johnson 125 ton part-revolution mechanical power press Serial No. 79063 did not incorporate an anti-repeat function for the two-hand controls used as guarding, exposing the operator to a point of operation hazard.     b) The South Bend OBI 150 ton part-revolution mechanical power press did not incorporate an anti-repeat function for the two-hand controls used as guarding, exposing the operator to a point of operation hazard.     Abatement Certification and Abatement Documentation Required.
Recent events (2)
  • — I (S) $1874.6
  • — Z (S) $2677.5

1910.217 E01 I

Serious Gravity 5 3 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment:    On or about April 19th, 2012 the employer had not established an inspection program to ensure the three part-revolution mechanical power presses were in safe operating condition.     Abatement Certification and Abatement Documentation Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 II

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:    On or about April 19th, 2012 the employer did not certify that periodic inspection(s) of their energy control program had been conducted.     Abatement Certification and Abatement Documentation Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View SMC METAL FABRICATORS INC's full OSHA safety record →