OSHKOSH, WI ·
OSHA Inspection: SMC METAL FABRICATORS INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SMC METAL FABRICATORS INC in 2100 S OAKWOOD RD, OSHKOSH, WI 54904 (NAICS 332999). OSHA activity number 333924306.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SMC METAL FABRICATORS INC
- Site address
- 2100 S OAKWOOD RD
- City
- OSHKOSH
- State
- WI
- ZIP
- 54904
- Mailing
- 2100 SO. OAKWOOD ROAD, OSHKOSH, WI 54904
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 92
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.217 B07 V C
- Issued
- Jun 22, 2012
- Abate by
- Aug 6, 2012
- Penalty
- Initial $2,678 · Current $1,875 Reduced
General-duty citation text
29 CFR 1910.217(b)(7)(v)(c): The two hand control system of mechanical power press(es) using part revolution clutches did not incorporate an antirepeat feature: a) The SBL South Bend Johnson 125 ton part-revolution mechanical power press Serial No. 79063 did not incorporate an anti-repeat function for the two-hand controls used as guarding, exposing the operator to a point of operation hazard. b) The South Bend OBI 150 ton part-revolution mechanical power press did not incorporate an anti-repeat function for the two-hand controls used as guarding, exposing the operator to a point of operation hazard. Abatement Certification and Abatement Documentation Required.
Recent events (2)
- · I (S) $1874.6
- · Z (S) $2677.5
1910.217 E01 I
- Issued
- Jun 22, 2012
- Abate by
- Aug 6, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment: On or about April 19th, 2012 the employer had not established an inspection program to ensure the three part-revolution mechanical power presses were in safe operating condition. Abatement Certification and Abatement Documentation Required.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 C06 II
- Issued
- Jun 22, 2012
- Abate by
- Aug 6, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: On or about April 19th, 2012 the employer did not certify that periodic inspection(s) of their energy control program had been conducted. Abatement Certification and Abatement Documentation Required.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at SMC Metal Fabricators INC
View SMC Metal Fabricators INC's full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 333924306.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.