Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: B.B.T. INDUSTRIAL ENGINE SERVICE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of B.B.T. INDUSTRIAL ENGINE SERVICE, INC. in 5858 BICENTENNIAL ST., SAN ANTONIO, TX 78219 (NAICS 332710). OSHA activity number 333962025.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch B.B.T. Industrial Engine Service, INC. — free Get an email when a new federal OSHA severe-injury report for B.B.T. Industrial Engine Service, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5858 BICENTENNIAL ST.
City
SAN ANTONIO
State
TX
ZIP
78219
Mailing
5858 BICENTENNIAL ST., SAN ANTONIO, TX 78219
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
11
Ownership type
A

11 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 11 instances 5 exposed
Issued
May 22, 2012
Abate by
Jun 13, 2012
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a) On or about March 19, 2012, and times prior thereto, specific procedures were not developed for multi energy source equipment such as the Storm- Vulcan crank grinder and the Bertoni & Cotti Crank grinder.  The energies as a minimum in the machine are hydraulic and electricity.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.147 C06 II

Serious Gravity 1 1 instance 5 exposed
Issued
May 22, 2012
Abate by
Jun 13, 2012
Penalty
Initial $1,620 · Current $972 Reduced
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:    a) On or about March 19, 2012, and times prior thereto, at this site, the employer did not conduct a periodic inspection of the energy control program.
Recent events (2)
  • — I (S) $972
  • — Z (S) $1620

1910.147 C07 I A

Serious Gravity 5 1 instance 5 exposed
Issued
May 22, 2012
Abate by
Jun 13, 2012
Penalty
Initial $2,700 · Current $1,620 Reduced
1910.147(c)(7)(i)(A): Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:    a) On or about March 19, 2012, and times prior thereto, at this site, employees did not receive training on the recognition of the hazardous and means necessary for energy isolation for the Storm Vulcan crank grinder and the Bertoni & Cotti crank grinder. Employee(s) exposed to a caught in hazard.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.212 A

Serious Gravity 5 1 instance 3 exposed
Issued
May 22, 2012
Abate by
Jun 13, 2012
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by struck-by hazard:    a) On or about March 19, 2012, and times prior thereto,  the rotating chuck on the Wilton VSG drill press was not guarded. Employee(s) exposed to a caught in hazard.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.212 B

Serious Gravity 5 1 instance 3 exposed
Issued
May 22, 2012
Abate by
Jun 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Anchoring fixed machinery. Machines designed for a fixed location shall be securely anchored to prevent walking or moving:    a) On or about March 19, 2012, and times prior thereto, the Wilton VSG drill press was not anchored to the floor. Employee (s) exposed to a struck by hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 F

Serious Gravity 5 2 instances 3 exposed
Issued
May 22, 2012
Abate by
Jun 13, 2012
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.219(f):  Gears were not guarded:    a) On or about March 19, 2012, and times prior thereto, the gears on the Sebastian Lathe were not guarded. Employee(s) exposed to a caught in hazard.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.305 B01 II

Serious Gravity 5 2 instances 3 exposed
Issued
May 22, 2012
Abate by
Jun 13, 2012
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed:    a) On or about March 19, 2012, and times prior thereto, disconnect panel box at the entrance of the shop, 10 breakers missing. Employee(s) exposed to an electrical shock.    b) On or about March 19, 2012, and times prior thereto, disconnect panel box for the pressure washer had a breaker missing. Employee(s) exposed to an electrical shock.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.305 B02 I

Serious Gravity 5 1 instance 3 exposed
Issued
May 22, 2012
Abate by
Jun 13, 2012
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose:    a) On or about March 19, 2012, and times prior thereto, at the Wilton Drill, the junction box did not have a face plate. Employee(s) exposed to an electrical shock.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
May 22, 2012
Abate by
Jun 13, 2012
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws:    a) On or about March 19, 2012, and times prior thereto, strain relief at the GEO Olcott  glass beading machine had the outer sheath pulled back exposing the internal conductors. Employee(s) exposed to an electrical shock.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.151 B

Other-than-serious 1 instance 11 exposed
Issued
May 22, 2012
Abate by
Jun 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.151(b): In the absence of an infirmary, clinic, or hospital in near proximity to the workplace which is used for the treatment of all injured employees, a person or persons were not adequately trained to render first aid:    a) On or about  March 19, 2012, and times prior thereto, there was no one trained to render first aid in a timely manner. Delay of medical response.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 3 exposed
Issued
May 22, 2012
Abate by
Jun 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1):  Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment:    a) On or about March 19, 2012, and times prior thereto, the panel boxes near the front of the shop were blocked. Employee(s) exposed to delay of isolating the equipment.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View B.B.T. Industrial Engine Service, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333962025.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.