MARIETTA, OH —
OSHA Inspection: DIMEX, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of DIMEX, LLC in 28305 STATE ROUTE 7, MARIETTA, OH 45750 (NAICS 326199). OSHA activity number 334088226.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DIMEX, LLC
- Site address
- 28305 STATE ROUTE 7
- City
- MARIETTA
- State
- OH
- ZIP
- 45750
- Mailing
- 28305 STATE ROUTE 7, MARIETTA, OH 45750
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 90
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.137 B02 VIII
- Issued
- May 18, 2012
- Abate by
- Jun 17, 2012
- Penalty
- Initial $2,975 · Current $2,975
General-duty citation text
29 CFR 1910.137(b)(2)(viii): Electrical protective equipment shall be subjected to periodic electrical tests. Test voltages and the maximum intervals between tests shall be in accordance with Table I-5 and Table I-6. a. At the workplace, the employer did not ensure that periodic electrical tests were completed on the electrical protective gloves used by maintenance employees.
Recent events (1)
- — Z (S) $2975
1910.212 A01
- Issued
- May 18, 2012
- Abate by
- Jun 17, 2012
- Penalty
- Initial $2,975 · Current $2,975
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. a. In the production department, ingoing nip points on the puller machines on lines 1, 2, 3, and 6 (Serial # 6-1908 ) were not guarded.
Recent events (1)
- — Z (S) $2975
1910.333 A
- Issued
- May 18, 2012
- Abate by
- Jun 17, 2012
- Penalty
- Initial $2,975 · Current $2,975
General-duty citation text
29 CFR 1910.333(a): "General." Safety-related work practices shall be employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work is performed near or on equipment or circuits which are or may be energized.The specific safety-related work practices shall be consistent with the nature and extent of the associated electrical hazards. a. At the workplace, for employees who routinely perform work on or near energized parts (230 VAC) such as testing, troubleshooting, voltage measuring, and other tasks in and around the screw oil heater, neither a flash hazard analysis was conducted to determine the proper protection required nor was a flash protection boundary established to protect employees from shock, arc flash, or arc blast. ABATEMENT NOTE: One method of abatement, among others, includes conducting a flash hazard analysis in compliance with NFPA 70E Standard for Electrical Safety in the Workplace to determine the flash protection boundary and the use of electrical protective equipment as necessary for the specific related hazards of each task.
Recent events (1)
- — Z (S) $2975
1910.333 C02
- Issued
- May 18, 2012
- Abate by
- Jun 17, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(c)(2): "Work on energized equipment." Only qualified persons may work on electric circuit parts or equipment that have not been deenergized under the procedures of paragraph (b) of this section. Such persons shall be capable of working safely on energized circuits and shall be familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools. a. At the workplace, for employees who routinely perform work on or near energized parts (230 VAC) such as testing, troubleshooting, voltage measuring, and other tasks in and around the screw oil heater, employees were not capable of working safely on energized circuits and were not familiar with the proper use of special precautionary techniques, personal protective equipment, and insulating and shielding materials to protect employees from shock, arc flash, or arc blast.
Recent events (1)
- — Z (S) $0
More inspections at Dimex, LLC
View Dimex, LLC's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334088226.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.