Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WEARSOX

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WEARSOX in 13700 LUTHE RD. BLDG B, HOUSTON, TX 77039 (NAICS 333132). OSHA activity number 334107422.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wearsox — free Get an email when a new federal OSHA severe-injury report for Wearsox is published. One employer, no account, unsubscribe in one click.
Establishment
WEARSOX
Site address
13700 LUTHE RD. BLDG B
City
HOUSTON
State
TX
ZIP
77039
Mailing
13700 LUTHE RD. BLDG B, HOUSTON, TX 77039
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333132
Employees
17
Ownership type
A

6 citations on file for this inspection.

1910.132 A

Serious Gravity 5 1 instance 7 exposed
Issued
May 31, 2012
Abate by
Jun 14, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered.    The employer does not ensure that employees don seatbelts while operating forklifts.  This condition was observed on or about April 30, 2012 at the facility where an employee was exposed to a struck-by hazard while operating a forklift without donning a seatbelt.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
May 31, 2012
Abate by
Jun 14, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.    The employer does not ensure that at least one method of machine guarding is used to protect the operator and other employees from rotating parts. This condition was observed on or about April 30, 2012 at the facility where an employee was exposed to a struck-by and caught-in hazards while working close to rotating chuck without a guard.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.219 F03

Serious Gravity 5 1 instance 3 exposed
Issued
May 31, 2012
Abate by
Jun 14, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed.    The employer does not ensure that sprocket wheels and chains that are less than 7 feet above the floor are guarded.     Instance a: This violation was observed on or about April 30, 2012 on the Eastside of the facility where an employee working in the Thermal Spray unit # 4 was exposed to struck-by and caught-in hazards when working close to chain and sprockets without guards.    Instance b: This violation was observed on or about April 30, 2012 on the Eastside of the facility where an employee working in the Thermal Spray unit # 5 was exposed to struck-by and caught-in hazards when working close to chain and sprockets without guards.    Instance c: This violation was observed on or about April 30, 2012 on the Eastside of the facility where an employee working in the Thermal Spray unit # 6 was exposed to struck-by and caught-in hazards when working close to chain and sprockets without guards.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.253 B04 III

Serious Gravity 5 1 instance 17 exposed
Issued
May 31, 2012
Abate by
Jun 14, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least.    The employer does not store the oxygen and acetylene compressed gas cylinders separately. This condition was observed on or about April 30, 2012 at the facility, where employees were exposed to explosion hazards while working in the facility without separation or barrier between the oxygen and acetylene cylinders.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.305 A02 I

Serious Gravity 5 4 instances 8 exposed
Issued
May 31, 2012
Abate by
Jun 14, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.305(a)(2)(i): Temporary electrical power and lighting installation(s) 600 volts, nominal, or less were used in prohibited manners.    The employer does not ensure that machines being used by employees were installed with permanent wiring. This condition was observed on or about April 30, 2012 at the facility, where employees were exposed to electrical hazards while working with machines powered by not permanent wiring.    Instance a: This violation was observed on or about April 30, 2012 in the facility where employees were exposed to an electrical hazard while operating a Wellsaw cutting bandsaw without permanent wiring.    Instance b: This violation was observed on or about April 30, 2012 in the facility where employees were exposed to an electrical hazard while operating a Littell spinning shuck without permanent wiring.    Instance c: This violation was observed on or about April 30, 2012 in the facility where employees were exposed to an electrical hazard while operating pipe rotary machines situated on Thermal Spray unit #1, #2, #3, #4, #5, and #6 without permanent wiring.    Instance d: This violation was observed on or about April 30, 2012 in the facility where employees were exposed to an electrical hazard while operating welder machines situated on Thermal Spray unit #1, #2, #3, #4, #5, and #6 without permanent wiring.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.334 A02 II

Serious Gravity 5 1 instance 1 exposed
Issued
May 31, 2012
Abate by
Jun 14, 2012
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service.    The employer does not ensure that damaged flexible electric cords were taken out of service. This condition was observed on or about April 30, 2012 at the facility, where employees were exposed to electrical hazards while working with machines powered by damaged flexible electric cords.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

View Wearsox's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334107422.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.