OSHA Inspection: NIAGARA THERMAL PRODUCTS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NIAGARA THERMAL PRODUCTS LLC in 3315 HASELEY DRIVE, NIAGARA FALLS, NY 14304 (NAICS 332410). OSHA activity number 334108636.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Niagara Thermal Products LLC — free Get an email when a new federal OSHA severe-injury report for Niagara Thermal Products LLC is published. One employer, no account, unsubscribe in one click.
Site address
3315 HASELEY DRIVE
City
NIAGARA FALLS
State
NY
ZIP
14304
Mailing
3315 HASELEY DRIVE, NIAGARA FALLS, NY 14304
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332410
Employees
100
Ownership type
A

5 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 4 exposed
Issued
May 29, 2012
Abate by
Jun 28, 2012
Penalty
Initial $4,208 · Current $3,156 Reduced
29 CFR 1910.147(c)(6)(i):     The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a) On or about 05/02/12, in the establishment, Employer did not conduct periodic inspections of their Lockout/Tagout(LOTO) procedures for machines such as, but not limited to: Twinfold Machines, Mechanical Power Presses: Niagara E-110 and Niagara E-200, Ovens, CNC Horizontal Milling Centers: HAASS, YASDA, OKUMA MC600, CNC Vertical Milling Center: OKUMA MX 45VAE for calendar years: 2007, 2008, 2009, 2010 and 2011.     ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $3155.63
  • — Z (S) $4207.5

1910.147 C06 II

Serious Gravity 5 1 instance 4 exposed
Issued
May 29, 2012
Abate by
Jun 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii):     The employer did not certify that periodic inspections of the energy control procedures had been performed:    a) On or about 05/02/12, in the establishment, Employer did not have certifications of Lockout/Tagout(LOTO) procedures periodic inspections for machines such as, but not limited to: Mechanical Power Presses (Niagara E-110 and E-200), Twinfold machines, CNC Machines and Ovens for calendar years: 2007, 2008, 2009, 2010 and 2011.     ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 5 1 instance 4 exposed
Issued
May 29, 2012
Abate by
Jun 28, 2012
Penalty
Initial $4,208 · Current $3,156 Reduced
29 CFR 1910.147(c)(7)(i)(A):     Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:    a) On or about 05/02/12, in the establishment, Employer did not provide training to authorized employees related to their machine-specific Lockout/Tagout(LOTO) procedures.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $3155.63
  • — Z (S) $4207.5

1910.147 F03 I

Serious Gravity 5 1 instance 2 exposed
Issued
May 29, 2012
Abate by
Jun 28, 2012
Penalty
Initial $4,208 · Current $3,156 Reduced
29 CFR 1910.147(f)(3)(i):     A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew:    a) On or about 05/02/12, in the production areas, two employees did not utilize a group Lockout/Tagout(LOTO) procedure while performing maintenance of Oven #3. Oven energy sources were electrical and air. Only two padlocks were used to isolate Oven's energy sources instead of using four padlocks.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $3155.63
  • — Z (S) $4207.5

1910.212 A03 II

Serious Gravity 10 1 instance 2 exposed
Issued
May 29, 2012
Abate by
Jun 28, 2012
Penalty
Initial $6,300 · Current $4,725 Reduced
29 CFR 1910.212(a)(3)(ii):     The  point of operation of machines whose operation exposed an employee to injury, was not guarded:    a) On or about 05/02/12, in the twinfold area, twinfold machine #500 operator's control panel was too close to point of operation. Therefore, when setting up this machine, employees could place one hand on the jog button and the other hand on the point of operation exposing them to amputations.    ABATEMENT DOCUMENTATION REQUIRED