Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JAVIER FLORES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JAVIER FLORES in 5601 ALICANTE DR, ARLINGTON, TX 76017 (NAICS 238160). OSHA activity number 334148632.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Javier Flores — free Get an email when a new federal OSHA severe-injury report for Javier Flores is published. One employer, no account, unsubscribe in one click.
Establishment
JAVIER FLORES
Site address
5601 ALICANTE DR
City
ARLINGTON
State
TX
ZIP
76017
Mailing
100 W CASON ST, IRVING, TX 75061
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.307 A02

Serious Gravity 5 1 instance 5 exposed
Issued
Oct 25, 2012
Abate by
Oct 30, 2012
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.307(a)(2):  Vertical and inclined belts (paragraphs (e)(3) and (4) of this section) if not more than 2 1/2 inches (6.35 cm) wide and running at a speed of less than one thousand (1,000) feet per minute, and if free from metal lacings or fastening were not guarded with a nip-point belt and pulley guard.      On or about May 02, 2012, the employer did not ensure that the belt of the Honda Air Compressor was guarded. The employees were exposed to an ingoing nip point hazard.
Recent events (1)
  • — Z (S) $2000

1926.307 D01

Serious Gravity 5 1 instance 5 exposed
Issued
Oct 25, 2012
Abate by
Oct 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.307(d)(1):  Pulley(s) with part(s) seven feet (2.128 m) or less from the floor or work platform were not guarded in accordance with the requirements specified in paragraphs  (m) and  (o) of this section:  Note:  Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than 6 ft. 6 in. (1.976 m) from the floor or platform may be guarded with a disk covering the spokes.      On or about May 02, 2012,  the employer did not ensure that the pulley of the Honda Air Compressor was guarded. The employees were exposed to an ingoing nip point hazard.
Recent events (1)
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 5 exposed
Issued
Oct 25, 2012
Abate by
Oct 30, 2012
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.501(b)(13):  Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor  did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502.    On or about May 02, 2012,  employees who were installing roofing material were not provided fall protection. The employees were exposed to falls of 8 feet 2 inches to the ground below.
Recent events (1)
  • — Z (S) $2000

View Javier Flores's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334148632.