Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: VIACON, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VIACON, INC. in 70 BANKS ROAD, STOCKBRIDGE, GA 30281 (NAICS 337212). OSHA activity number 334197431.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Viacon, INC. for free Get an email when a new federal OSHA severe-injury report for Viacon, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
VIACON, INC.
Site address
70 BANKS ROAD
City
STOCKBRIDGE
State
GA
ZIP
30281
Mailing
70 BANKS ROAD, STOCKBRIDGE, GA 30281
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337212
Employees
60
Ownership type
Private (A)

7 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 24, 2012
Abate by
Oct 9, 2012
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.147(c)(1):     The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    On or about 05/03/12 at 70 Banks Road, Stockbridge,Ga; employees were exposed to struck-by, caught-in, amputation, and electrical hazards where the employer failed to provide a Lockout/Tagout program for the employees:    1. Edge Banding machine- pneumatic, electric  2. CNC machine- pneumatic, electric
Recent events (2)
  • · I (S) $2940
  • · Z (S) $4900

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 24, 2012
Abate by
Oct 9, 2012
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about 05/03/12 at 70 Banks Road, Stockbridge, Ga; employees were exposed to amputation hazards where in-going nip points existed during cleaning operations of the Holz-her, Triathelon, Edge bander machine. Employees cleaned the adhesive from the rotating wheel by hand.
Recent events (2)
  • · I (S) $2940
  • · Z (S) $4900

1910.212 B

Serious Gravity 1 3 instances 60 exposed
Issued
Aug 24, 2012
Penalty
Initial $1,785 · Current $1,071 Reduced
29 CFR 1910.212(b):     Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    On or about 05/03/12 at 70 Banks Road, Stackbridge, Ga; employees were exposed to struck-by hazards while performing drilling operations with a floor drill press that was not permanently mounted to the floor.
Recent events (2)
  • · I (S) $1071
  • · Z (S) $1785

1910.242 B

Serious Gravity 10 60 exposed
Issued
Aug 24, 2012
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.242(b):     Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    On or about 05/03/12 at 70 Banks Road, Stockbridge, Ga; employees were exposed to potential hazards while performing cleaning operations with improperly regulated air nozzles. Employees were observed cleaning themselves with compressed air that was measured at 98 PSI.
Recent events (2)
  • · I (S) $2940
  • · Z (S) $4900

1910.303 B02

Serious Gravity 1 2 instances 60 exposed
Issued
Aug 24, 2012
Penalty
Initial $1,785 · Current $1,071 Reduced
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    On or about 05/03/12 at 70 Banks Road, Stockbridge, Ga; employees were exposed to electrical hazards while building cabinets with electrical connections that did not meet the listed labeling requirements of an industrial setting:    a. Power strips- energizing corded hand tools  b. Metallic duplex outlet box used as a drop pendant- energizing two Delta, 12" drill presses.
Recent events (2)
  • · I (S) $1071
  • · Z (S) $1785

1910.303 B07 I

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 24, 2012
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1910.303(b)(7)(i):     Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment    On or about 05/03/12 at 70 Banks Road, Stockbridge, Ga; employees were exposed to electrical hazards where 110 V electrical outlet boxes had knock-outs that were missing.
Recent events (2)
  • · I (S) $1785
  • · Z (S) $2975

1910.178 L01 I

Other-than-serious 1 instance 60 exposed
Issued
Aug 24, 2012
Abate by
Oct 9, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(i):     The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    On or about 05/03/12 at 70 Banks Road, Stockbridge, Ga; employees were exposed to struck-by hazards where the employer failed to train, evaluate, and certify all powered industrial truck operators.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Viacon, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334197431.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.