Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HARMAR

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HARMAR in 18505 EAST 163RD STREET, LAKE WINNEBAGO, MO 64034 (NAICS 532291). OSHA activity number 334250453.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Harmar — free Get an email when a new federal OSHA severe-injury report for Harmar is published. One employer, no account, unsubscribe in one click.
Establishment
HARMAR
Site address
18505 EAST 163RD STREET
City
LAKE WINNEBAGO
State
MO
ZIP
64034
Mailing
18505 EAST 163RD STREET, LAKE WINNEBAGO, MO 64034
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
532291
Employees
50
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 8, 2012
Abate by
Jul 8, 2012
Penalty
Initial $3,060 · Current $2,142 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a) There was no written lockout tagout program when employees have to work on equipment for maintenance activities, such as, but not limited to the saws which have electric and air power.
Recent events (2)
  • — I (S) $2142
  • — Z (S) $3060

1910.212 A01

Serious Gravity 1 2 instances 8 exposed
Issued
Jun 8, 2012
Abate by
Jul 8, 2012
Penalty
Initial $2,295 · Current $1,607 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) Dumbwaiter Section:  Drill Presses, such as, but not limited to, the Central Machinery Drill Press, did not have the rotating chuck guarded.    (b) Seat Assembly:  The Pinnacle Guardian Power 16 speed drill press did not have the rotating chuck guarded.
Recent events (2)
  • — I (S) $1606.5
  • — Z (S) $2295

1910.242 B

Serious Gravity 1 1 instance 4 exposed
Issued
Jun 8, 2012
Abate by
Jul 8, 2012
Penalty
Initial $2,295 · Current $1,607 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    (a) Track Area:  The Air Nozzle being used for cleaning by the Bridgeport Milling Machine and saw was operating at 50 p.s.i.
Recent events (2)
  • — I (S) $1606.5
  • — Z (S) $2295

1910.303 B02

Serious Gravity 1 4 instances 30 exposed
Issued
Jun 8, 2012
Abate by
Jul 8, 2012
Penalty
Initial $2,295 · Current $1,607 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a) Track Area:  Pendant boxes, such as, but not limited to, the 4 plex electrical pendant box that was used to power 2 vacuum cleaners was not used or installed in accordance with the listing or labelling.  The 4 plex electrical pendant box was made of metal and had knockouts which was listed or labelled to be used with rigid conduit and mounted to a wall or piece of equipment.
Recent events (2)
  • — I (S) $1606.5
  • — Z (S) $2295

1910.305 F01

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 8, 2012
Abate by
Jul 8, 2012
Penalty
Initial $2,295 · Current $1,607 Reduced
29 CFR 1910.305(f)(1): All conductors used for general wiring were not insulated unless otherwise permitted in this subpart:    (a) Battery Charger Area:  GNB Ferocharger Battery Charger did not have adequate insulation as there were nicks in the outer insulation of the red battery cable exposing bare wires.
Recent events (2)
  • — I (S) $1606.5
  • — Z (S) $2295

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 8, 2012
Abate by
Jul 8, 2012
Penalty
Initial $2,295 · Current $1,607 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    (a) Battery Charger Area:  The Douglas Legacy Battery Charger for the Bendi Lift did not have adequate strain relief as there was not adequate strain relief where the battery cables joined to the connection to the fitting that is plugged into the battery.
Recent events (2)
  • — I (S) $1606.5
  • — Z (S) $2295

1910.1200 E01

Serious Gravity 1 2 instances 4 exposed
Issued
Jun 8, 2012
Abate by
Jul 8, 2012
Penalty
Initial $2,295 · Current $1,607 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    (a) There were no written hazard communication program for employees using hazardous chemicals, such as, but not limited to, acetone, and denatured alcohol.  The written hazard communication program is required to include how chemicals will be labeled and other forms of warning; material safety data sheets, and employee information and training.
Recent events (2)
  • — I (S) $1606.5
  • — Z (S) $2295

View Harmar's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334250453.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.