VESTAL, NY —
OSHA Inspection: A & E ROOFING & SIDING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of A & E ROOFING & SIDING in 504 HARVARD STREET, VESTAL, NY 13850 (NAICS 238160). OSHA activity number 334256328.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A & E ROOFING & SIDING
- Site address
- 504 HARVARD STREET
- City
- VESTAL
- State
- NY
- ZIP
- 13850
- Mailing
- 215 W. FRANKLIIN STREET, MORRISVILLE, PA 19067
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.404 B01 II
- Issued
- Jun 1, 2012
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrutpers for personal protection: a) 504 Harvard Street, east side of roof, on or about 5-10-12: Employees were operating a hand held circular saw and various other power tools, powered through a duplex receptacle and extension cord that was not protected by a ground fault circuit interrupter (GFCI).
Recent events (1)
- — Z (S) $1600
1926.501 B13
- Issued
- Jun 1, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. a) 504 Harvard Street, west side of roof, on or about 5-10-12: Employees were working on a 4:12 pitch roof, without fall protection, exposing the employees to a fall hazard of 9 feet 6 inches.
Recent events (1)
- — Z (S) $2000
1926.503 A01
- Issued
- Jun 1, 2012
- Abate by
- Jul 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) 504 Harvard Street, west side of roof, on or about 5-10-12: Employees were working on a 4:12 pitch roof, without the training necessary for those employees to recognize the hazards associated with their work. ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (1)
- — Z (S) $0
1926.1053 B01
- Issued
- Jun 1, 2012
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) 504 Harvard Street, east side of roof, on or about 5-10-12: Employees were accessing a roof using a portable ladder that was not extended 3 feet above the landing surface, exposing the employee to a fall hazard of 10 feet 6 inches.
Recent events (1)
- — Z (S) $1600
More inspections at A & E Roofing & Siding
View A & E Roofing & Siding's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334256328.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.