Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: S & R CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of S & R CORPORATION in ROOSEVELT AVE BRIDGE AT CSX LINE, SPRINGFIELD, MA 01104 (NAICS 237310). OSHA activity number 334257912.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch S & R Corporation — free Get an email when a new federal OSHA severe-injury report for S & R Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
S & R CORPORATION
Site address
ROOSEVELT AVE BRIDGE AT CSX LINE
City
SPRINGFIELD
State
MA
ZIP
01104
Mailing
706 BROADWAY STREET, LOWELL, MA 01854
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
Employees
60
Ownership type
A

4 citations on file for this inspection.

1926.95 A

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 24, 2012
Penalty
Initial $4,900 · Current $4,200 Reduced
29 CFR 1926.95(a):     Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, and maintained in a sanitary and reliable condition wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact:    Roosevelt Bridge at CSX Line, Springfield, MA    On May 10 and 11, 2012, the employer did not provide appropriate personal protective equipment for two employees exposed to electrical hazards who were instructed to use rivet busters to chip away the concrete underside of a bridge to find the location of a conduit containing an energized 13.8KV conductor.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $4900

1926.416 A01

Serious Gravity 10 2 exposed
Issued
Jul 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.416(a)(1):     Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:    Roosevelt Bridge at CSX Line, Springfield, MA    On May 10 and 11, 2012, the employer instructed two employees to use rivet busters to chip away the concrete underside of a bridge to find the location of the conduit for an energized 13.8KV conductor.  The employer did not have  the circuit de-energized or ensure effective guarding for those employees exposed to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.850 D

Deleted Serious Gravity 10 2 exposed
Issued
Jul 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.850(d):     When it was necessary to maintain power, water or other utilities during demolition, such lines were not temporarily relocated, as necessary, and protected.    Roosevelt Bridge at CSX Line, Springfield, MA    On May 11, 2012 and at times prior, the employer dismantled portions of a bridge  which contained  a 13.8KV energized conductor .  The employer instructed two employees to use rivet busters to chip away part of the concrete underside to find the location of the energized conduit, resulting in severe burn injury to one employee.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Other-than-serious 1 instance 2 exposed
Issued
Jul 24, 2012
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.134(e)(1):     The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    Roosevelt Bridge at CSX Line, Springfield, MA    On May 11, 2012 and at times prior, employees were required to wear positive air half mask- and allowed to voluntarily wear filtered half mask respirators without the required medical evaluation.  The employees were exposed to hazards relating to increased respiratory workloads.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3500

View S & R Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334257912.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.