BRIGHTON, CO —
OSHA Inspection: COCOL CONSTRUCTION, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COCOL CONSTRUCTION, LLC in 90 S. 18TH AVE., BRIGHTON, CO 80601 (NAICS 236220). OSHA activity number 334295722.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COCOL CONSTRUCTION, LLC
- Site address
- 90 S. 18TH AVE.
- City
- BRIGHTON
- State
- CO
- ZIP
- 80601
- Mailing
- 5305 ALTURA ST., DENVER, CO 80239
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 5
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 G01 VII
- Issued
- Aug 10, 2012
- Abate by
- Aug 25, 2012
- Penalty
- Initial $1,020 · Current $1,020
General-duty citation text
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. (a) Cocol Construction, LLC, 90 S. 18th Ave., Brighton, CO 80601: On and before May 15, 2012, the exposing employer did not ensure that employees working off an 18" aluminum scaffold plank were protected from falling by an adequate scaffold system, or fall protective system. Employer had set up the scaffold plank between two 10 foot ladders which were positioned on two levels of different heights without any fall protective measures in place such as guard rails. Condition exposed employees to fall hazards of approximately 15 feet.
Recent events (1)
- — Z (S) $1020
1926.451 G04 I
- Issued
- Aug 10, 2012
- Abate by
- Aug 25, 2012
- Penalty
- Initial $1,020 · Current $1,020
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms on a scaffold system. (a) Cocal Construction, LLC, 90 S. 18th Ave., Brighton, CO 80601: On and before May 15, 2012, the exposing employer did not install guard rails along all of the open sides of a scaffold system. Employer had set up the plank between two 10 foot ladders which were positioned on two levels of different heights without any fall protective measures in place such as guard rails. Condition exposed employees to fall hazards of approximately 15 feet.
Recent events (1)
- — Z (S) $1020
1926.451 H01
- Issued
- Aug 10, 2012
- Abate by
- Aug 25, 2012
- Penalty
- Initial $1,020 · Current $1,020
General-duty citation text
29 CFR 1926.451(h)(1): Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, or guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects. (a) Cocol Construction, LLC, 90 S. 18th Ave., Brighton, CO 80601: On and before May 15, 2012, the exposing employer did not install toe boards or some other means of protection for employees below the working surface. Condition exposed employees to struck by hazards from falling objects.
Recent events (1)
- — Z (S) $1020
1926.1053 B01
- Issued
- Aug 10, 2012
- Abate by
- Aug 25, 2012
- Penalty
- Initial $1,020 · Current $1,020
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension was not possible because of the ladder's length, the ladder was not secured at its top to a rigid support that would not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder. (a) Cocol Construction, 90 South 18th Ave., Brighton, CO 80601: On and before May 15, 2012, the exposing employer did not ensure that a ladder in use to access the second floor of a construction project extened at least 3 feet above the landing surface. Condition exposed employees to fall hazards of approximately 15 feet while climbing the ladder.
Recent events (1)
- — Z (S) $1020
1926.454 A
- Issued
- Aug 10, 2012
- Abate by
- Aug 25, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer failed to ensure that each employee who performs work while on a scaffold was trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. (a) Cocol Construction, LLC, 90 S. 18th Ave., Brighton, CO 80601: On and before May 15, 2012, the exposing employer did not ensure that each employee who performs work while on a scaffold was trained by a qualified person in the subject matter to recognize the hazards, specifically fall hazards, associated with the type of scafold being used. Condition exposed employees to fall hazards of approximately 15 feet while using the scaffold.
Recent events (1)
- — Z (O) $0
1926.1060 A
- Issued
- Aug 10, 2012
- Abate by
- Aug 25, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a): The employer failed to provide a training program for each employee using ladders and stairways, as necessary. (a) Cocol Construction, LLC, 90 S. 18th Ave., Brighton, CO 80601: On and before May 15, 2012, the exposing employer failed to provide training to his employees utilzing ladders. The employer failed to provide a training program which enabled each employee to recognize hazards related to ladders and stairways, and train each employee in the procedures to be followed to minimize these hazards. Condition exposed employees utilzing ladders to fall hazards of approximately 15 feet.
Recent events (1)
- — Z (O) $0
More inspections at Cocol Construction, LLC
View Cocol Construction, LLC's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334295722.