DOUGLASVILLE, GA —
OSHA Inspection: AMBROSIO JUAREZ MASONRY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMBROSIO JUAREZ MASONRY, INC. in 2777 CHAPEL HILL ROAD, DOUGLASVILLE, GA 30135 (NAICS 238140). OSHA activity number 334323912.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMBROSIO JUAREZ MASONRY, INC.
- Site address
- 2777 CHAPEL HILL ROAD
- City
- DOUGLASVILLE
- State
- GA
- ZIP
- 30135
- Mailing
- 1652 PHARRS RD., SNELLVILLE, GA 30078
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.95 A
- Issued
- Jul 20, 2012
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.95(a): "Application." Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact. North side of building, scaffold: Employees were not required to wear gloves while handling chemicals such as mortar, exposing employees to skin irritants and chemical burns.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.451 B01
- Issued
- Jul 20, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: North and East sides of building, scaffold: The employer exposed employees to fall hazards while working over 10 feet above the ground from a fabricated frame scaffold with platforms that were not fully planked.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.451 E01
- Issued
- Jul 20, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. North side of building, scaffold: The employer exposed employees to fall hazards of over 15 feet as a secure ladder was not used by employees to access the scaffolding platform.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.451 G01
- Issued
- Jul 20, 2012
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. North and East sides of the building, scaffold: The employer exposed employees to fall hazards while working over 15 feet above the ground from a fabricated frame scaffold which did not have a complete guardrail system, due to the mid-rails, cross-bracing, and end-rails not being installed.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.451 B05 I
- Issued
- Jul 20, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(b)(5)(i): Each end of a platform 10 feet or less in length shall not extend over its support more than 12 inches (30 cm) unless the platform is designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end. North side of building, scaffold: The employer exposed employees to fall hazards of 15 feet by having scaffold planks extending beyond their supports by over 18 inches.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.501 B04 II
- Issued
- Jul 20, 2012
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface shall be protected from tripping in or stepping into or through holes (including skylights) by covers. East side of building, pavement: The employer exposed employees to tripping hazards from unprotected holes; the holes were approximately eight (8) inches wide.
Recent events (2)
- — I (S) $0
- — Z (S) $1600
More inspections at Ambrosio Juarez Masonry, INC.
View Ambrosio Juarez Masonry, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334323912.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.