RAVENNA, NE —
OSHA Inspection: SUN TECH INDUSTRIES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SUN TECH INDUSTRIES, INC. in 41958 HWY 2, RAVENNA, NE 68869 (NAICS 326199). OSHA activity number 334390911.
Where did this inspection happen?
- Establishment
- SUN TECH INDUSTRIES, INC.
- Site address
- 41958 HWY 2
- City
- RAVENNA
- State
- NE
- ZIP
- 68869
- Mailing
- 41958 HWY 2, RAVENNA, NE 68869
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 11
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $1360.00 · Current $680.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: In the northwest corner of the facility next to the pellet dryer: The employer provided an air nozzle that did not have a chip guard to reduce the pressure of the air to less than 30 p.s.i. The air compressor was set at 115 p.s.i. and was not regulated to less than 30p.s.i.
Recent events (2)
- — I (S) $680
- — Z (S) $1360
1910.303 B01
- Issued
- Abate by
- Penalty
- Initial $1360.00 · Current $680.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: In the production area of Sun Tech Industries, Inc.: Employees were exposed to the following electrical equipment that was not free of recognized hazards. 1. On the Pelletron located in the northwest corner of the facility: the employer had installed an electrical switch to power the unit on and off. The electrical box was not designed for this type of application. 2. On the Sonic Welder in the center of the facility: the employer had made a pigtail to adapt the electrical interlock type receptacle to a standard 110 volt household style receptacle.
Recent events (2)
- — I (S) $680
- — Z (S) $1360
More inspections at SUN TECH INDUSTRIES, INC.
RAVENNA, NE—2014-01-13 00:00:00
SUN TECH INDUSTRIES, INC.
View SUN TECH INDUSTRIES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
PETALUMA, CA—2026-07-10
LABCON NORTH AMERICA
KEEWATIN, MN—2026-07-09
111565 - TACKLE TAMER PRODUCTS INC
EAST FLAT ROCK, NC—2026-07-09
161517 - ELKAMET, INC.
LANESBOROUGH, MA—2026-07-08
LANSEN MOLD CO., INC.
More inspections in NE
OMAHA, NE—2026-07-10
WINGSTOP
LINCOLN, NE—2026-07-01
SMITHFIELD PACKAGED MEATS CORP.
LINCOLN, NE—2026-06-30
PATRIOT PLUMBING, HEATING & AC
BLAIR, NE—2026-06-30
NATUREWORKS LLC
EDISON, NE—2026-06-30
AG VALLEY COOP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334390911.