OSHA Inspection: ESCOBEDO CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ESCOBEDO CONSTRUCTION in 4001 S. SAM HOUSTON PKWY EAST, HOUSTON, TX 77047 (NAICS 423330). OSHA activity number 334432358.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Escobedo Construction — free Get an email when a new federal OSHA severe-injury report for Escobedo Construction is published. One employer, no account, unsubscribe in one click.
Site address
4001 S. SAM HOUSTON PKWY EAST
City
HOUSTON
State
TX
ZIP
77047
Mailing
11135 LONGHORN CIRCLE, HOUSTON, TX 77041
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423330
Employees
5
Ownership type
A

1 citation on file for this inspection.

1926.501 B10

Repeat Gravity 5 1 instance 2 exposed
Issued
Aug 22, 2012
Penalty
Initial $4,000 · Current $4,000
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels were not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.    South side of the structure; employees installed corrugated panels  on a low slope roof with a 4:12 pitch that had unprotected sides and edges at 30 feet, 6 inches, exposing employees to fall hazards.     ESCOBEDO CONSTRUCTION WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETYAND HEALTH STANDARD 1926.501(B)(10) CONTAINED IN OSHA INSPECTION NUMBER 280191, CITATION NUMBER 1, ITEM NUMBER 1, WITH RESPECT TO A WORKPLACE LOCATED AT 6827 GRIGGS ROAD, HOUSTON, TX 77023.  THIS FILE BECAME A FINAL ORDER ON MAY 15, 2012.
Recent events (1)
  • — Z (R) $4000

View Escobedo Construction's full OSHA safety record →