Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: ORBIS CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ORBIS CORPORATION in 200 ELM STREET, URBANA, OH 43078 (NAICS 326199). OSHA activity number 334435542.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Orbis Corporation for free Get an email when a new federal OSHA severe-injury report for Orbis Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
ORBIS CORPORATION
Site address
200 ELM STREET
City
URBANA
State
OH
ZIP
43078
Mailing
200 ELM STREET, URBANA, OH 43078
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
313
Ownership type
Private (A)

6 citations on file for this inspection.

1910.23 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 30, 2012
Abate by
Sep 11, 2012
Penalty
Initial $2,550 · Current $1,785 Reduced
29 CFR 1910.23(c)(1):     Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides,    a) The elevated platform for the molding machine dies were not equipped wwith a guard railing system
Recent events (2)
  • · I (S) $1785
  • · Z (S) $2550

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 30, 2012
Abate by
Aug 20, 2012
Penalty
Initial $2,550 · Current $1,785 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.    a) Machine guarding was not provided on the bandsaw to prevent employee exposure to the unused portion of the saw blade.
Recent events (2)
  • · I (S) $1785
  • · Z (S) $2550

1910.219 C02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 30, 2012
Abate by
Aug 20, 2012
Penalty
Initial $2,550 · Current $1,785 Reduced
29 CFR 1910.219(c)(2)(i):     All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires.    a) The shaft attached to the motor drive for the Shreadar was not guarded to prevent employees exposure from contact with rotating parts.
Recent events (2)
  • · I (S) $1785
  • · Z (S) $2550

1910.303 G02 I

Serious Gravity 1 2 instances 1 exposed
Issued
Jul 30, 2012
Penalty
Initial $2,168 · Current $1,518 Reduced
29 CFR 1910.303(g)(2)(i):     Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidentalcontact by use of approved cabinets or other forms of approved enclosures or by any of the following means:    a) Junction box for the Vacrum unit was not covered to prevent employees from contact with live parts.  b) Electrical Amp meter guage for the nozzle tester was not covered in that the guage glass enclosure was broken, exposing employees to live parts.
Recent events (2)
  • · I (S) $1517.6
  • · Z (S) $2168

1910.305 B01 II

Serious Gravity 1 2 instances 1 exposed
Issued
Jul 30, 2012
Penalty
Initial $2,168 · Current $1,518 Reduced
29 CFR 1910.305(b)(1)(ii):     Unused openings in cabinets, boxes, and fittings shall be effectively closed.    a) Knockout covers were missing from the Main disconnect box for press #504.  b) Knockout covers were missing from the Junction box in the tool room.
Recent events (2)
  • · I (S) $1517.6
  • · Z (S) $2168

1910.305 G02 III

Serious Gravity 1 4 instances 2 exposed
Issued
Jul 30, 2012
Penalty
Initial $2,168 · Current $1,518 Reduced
29 CFR 1910.305(g)(2)(iii):     Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.    a) Flexible cord attached to Pedestial mounted fan motor was not equipped with strain relief to prevent movement or damage to conductors.    b) Flexible cord attached to Nozzle testing unit was not equipped with strain relief to prevent movement or damage to conductors.
Recent events (2)
  • · I (S) $1517.6
  • · Z (S) $2168

View Orbis Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334435542.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.