FENTON, MO ·
OSHA Inspection: CONTROL DEVICES, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CONTROL DEVICES, LLC in 1555 LARKIN WILLIAMS RD, FENTON, MO 63026 (NAICS 332721). OSHA activity number 334453743.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONTROL DEVICES, LLC
- Site address
- 1555 LARKIN WILLIAMS RD
- City
- FENTON
- State
- MO
- ZIP
- 63026
- Mailing
- 1555 LARKIN WILLIAMS RD, FENTON, MO 63026
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332721
- Employees
- 240
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.147 C07 I A
- Issued
- Jul 10, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $3,600 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: a. Where work requiring lockout, such as, but not limited to, changing cut-off saw blades and changing screw machine gears, employees performing those tasks were not trained on lockout. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- · I (S) $2520
- · Z (S) $3600
1910.147 D04 I
- Issued
- Jul 10, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a. Where work requiring lockout, such as, but not limited to, changing cut-off saw blades and changing screw machine gears, the equipment was not locked out. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.176 B
- Issued
- Jul 10, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $2,700 · Current $1,890 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: a. A tote of fluid was placed on second tier of racking, where the racking was without wire grating; the tote was placed on the cross beams in such a manner that it could have become dislodged. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- · I (S) $1890
- · Z (S) $2700
1910.215 A04
- Issued
- Jul 10, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $2,700 · Current $1,890 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a. Grinders were used with work rests either not adjusted to a maximum opening of one eigth inch or without a work rest; several examples existed. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- · I (S) $1890
- · Z (S) $2700
1910.215 B09
- Issued
- Jul 10, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a. Grinders were used with guards either not adjusted to a maximum opening of one fourth inch or without a guard; several examples existed. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.178 L01 II
- Issued
- Jul 10, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck: a. Employees were allowed to operate a forklift without completing the training established by the company. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.178 L02 III
- Issued
- Jul 10, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(2)(iii): All operator training and evaluation was not conducted by persons who had the knowledge, training, and experience to train powered industrial truck operators and evaluate their competence a. Employee was trained by another employee who was not trained himself, did not go through the company training program, and was a designated trainer; employer did not ensure that training was conducted according to their own procedures. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 E01
- Issued
- Jul 10, 2012
- Abate by
- Sep 12, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. A chemical hazard communication program was not developed, established, and written; chemical products included cutting oils, lubricants, and other chemical products. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Control Devices, LLC
View Control Devices, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332721)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334453743.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.