FENTON, MO —
OSHA Inspection: CONTROL DEVICES LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CONTROL DEVICES LLC in 1555 LARKIN WILLIAMS ROAD, FENTON, MO 63026 (NAICS 332119). OSHA activity number 343524997.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONTROL DEVICES LLC
- Site address
- 1555 LARKIN WILLIAMS ROAD
- City
- FENTON
- State
- MO
- ZIP
- 63026
- Mailing
- 1555 LARKIN WILLIAMS ROAD, FENTON, MO 63026
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332119
- Employees
- 260
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Oct 16, 2018
- Abate by
- Dec 4, 2018
- Penalty
- Initial $12,934 · Current $9,054 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: At 1555 Larkin Williams Road, Fenton, Missouri, on 10/03/18, the rotating parts belonging to the following machines were unguarded: Assembly Department: a/ Delta Drilling Machine, #0258. Secondary Operations Department: a/ Bridgeport Milling Machine, s/n J-169622. b/ Delta Drilling Machine, s/n 025102W5040. c/ Hardinge Lathe, m/n 94-1089, s/n PCB10002. d/ Dake Drilling Machine, #0062. e/ Dake Drilling Machine, #0063. f/ Warner & Swasey Lathe, m/n 3. Model Shop: a/ Ryobi Vertical Belt Sander, #0408. b/ Wilkon Circular Sander.
Recent events (2)
- — I (S) $9053.8
- — Z (S) $12934
1910.212 B
- Issued
- Oct 16, 2018
- Abate by
- Dec 4, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: At 1555 Larkin Williams Road, Fenton, Missouri, specifically inside of the Assembly Department, the Delta Drilling Machine, #0258, was not anchored to the fixed table. This violation was noted on 10/03/18.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Control Devices LLC