OSHA Inspection: PENN STUCCO INC.

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of PENN STUCCO INC. in 1824 CHRISTIAN ST, PHILADELPHIA, PA 19146 (NAICS 238140). OSHA activity number 334480738.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Penn Stucco INC. — free Get an email when a new federal OSHA severe-injury report for Penn Stucco INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PENN STUCCO INC.
Site address
1824 CHRISTIAN ST
City
PHILADELPHIA
State
PA
ZIP
19146
Mailing
13 LEE DRIVE, POTTSTOWN, PA 19464
Inspection type
Programmed Related (J)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
A

8 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 13, 2012
Abate by
Sep 14, 2012
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.451(b)(1):     Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:    a) Jobsite: 1824 Christian St, Philadelphia, PA. - On or about 5/29/12, the working platforms on the supported tubular welded frame scaffold were missing planks. Employees were performing masonry operations from the 3rd working platform, approximately 18 ft. above ground level.
Recent events (1)
  • — Z (S) $2000

1926.451 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 13, 2012
Abate by
Sep 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(4):     Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm).    a) Jobsite: 1824 Christian St, Philadelphia, PA. - On or about 5/29/12, the end of the platforms on the supported tubular welded frame scaffold  did not extended over the centerline of their support by at least 6 inches. Employees were performing masonry operations from the 3rd working platform, approximately 18 ft. above ground level.
Recent events (1)
  • — Z (S) $0

1926.451 B05 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 13, 2012
Abate by
Sep 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(5)(i):     Each end of a platform 10 feet or less in length shall not extend over its support more than 12 inches (30 cm) unless the platform is designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end.    a) Jobsite: 1824 Christian St, Philadelphia, PA. - On or about 5/29/12, the cantilevered portion of the platforms on the supported tubular welded frame scaffold extended more than 12 inches over their support which exposed the employees to tip over hazards. Employees were performing masonry operations from the 3rd working platform, approximately 18 ft. above ground level.
Recent events (1)
  • — Z (S) $0

1926.451 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 13, 2012
Abate by
Sep 14, 2012
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.451(c)(1):     Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:    a) Jobsite: 1824 Christian St, Philadelphia, PA. - On or about 5/29/12, the supported tubular welded frame scaffold, measuring approximately 25 ft in elevation and 5 ft in width, was not restrained from tipping or falling over.  Employees were performing masonry operations from the 3rd working platform, approximately 18 ft. above ground level.
Recent events (1)
  • — Z (S) $2000

1926.451 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 13, 2012
Abate by
Sep 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(2):     Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.    a) Jobsite: 1824 Christian St, Philadelphia, PA. - On or about 5/29/12, the supported tubular welded frame scaffold, was at risk of collapsing or shifting because the legs did not bear on base plates. Employees were performing masonry operations from the 3rd working platform, approximately 18 ft. above ground level
Recent events (1)
  • — Z (S) $0

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 13, 2012
Abate by
Sep 14, 2012
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.451(e)(1):     When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.    a) Jobsite: 1824 Christian St, Philadelphia, PA. - On or about 5/29/12, a safe means of access was not provided for employees working on the supported tubular welded frame scaffold. Employees were performing masonry operations from the 3rd working platform, approximately 18 ft. above ground level.
Recent events (1)
  • — Z (S) $2000

1926.451 G01 VII

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 13, 2012
Abate by
Sep 14, 2012
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.451(g)(1)(vii):     For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    a) Jobsite: 1824 Christian St, Philadelphia, PA. - On or about 5/29/12, employees were not provided with a fall protection system while working from a supported tubular welded frame scaffold.  Employees were performing masonry operations from the 3rd working platform, approximately 18 ft. above ground level.
Recent events (1)
  • — Z (S) $2000

1926.454 A

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 13, 2012
Abate by
Sep 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a):     The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the following areas, as applicable:    a) Jobsite: 1824 Christian St, Philadelphia, PA. - On or about 5/29/12, employees were not trained to recognize the hazards associated with their work while working from a  supported tubular welded frame scaffold.
Recent events (1)
  • — Z (S) $0

View Penn Stucco INC.'s full OSHA safety record →