Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: H. NAGEL & SON CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of H. NAGEL & SON CO. in 15022 BROOKVILLE-PYRMONT ROAD, BROOKVILLE, OH 45309 (NAICS 311211). OSHA activity number 334503745.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch H. Nagel & SON CO. for free Get an email when a new federal OSHA severe-injury report for H. Nagel & SON CO. is published. One employer, no account, unsubscribe in one click.
Establishment
H. NAGEL & SON CO.
Site address
15022 BROOKVILLE-PYRMONT ROAD
City
BROOKVILLE
State
OH
ZIP
45309
Mailing
2428 CENTRAL PARKWAY, CINCINNATI, OH 45214
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311211
Employees
10
Ownership type
Private (A)

18 citations on file for this inspection.

1910.23 A05

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 20, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,850 · Current $2,700 Reduced
29 CFR 1910.23(a)(5):     Every pit and trapdoor floor opening, infrequently used, shall be guarded by a floor opening cover of standard strength and construction. While the cover is not in place, the pit or trap opening shall be constantly attended by someone or shall be protected on all exposed sides by removable standard railings.    a.  In the Midds wheat dump building an employee was exposed to a fall hazard from a pit floor opening measuring 26 inches in width, approximately 8' in length and approximately 10' in depth.    b.  In the concrete walkway area between the concrete silos and mill building an employee was exposed to a fall hazard from a partially removed metal cover from a fit opening measuring 16 inches in width, 18 inches in length and 16' in depth.
Recent events (2)
  • · I (S) $2700
  • · Z (S) $3850

1910.23 A10

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 20, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,850 · Current $2,700 Reduced
29 CFR 1910.23(a)(10):     Where doors or gates open directly on a stairway, a platform shall be provided, and the swing of the door shall not reduce the effective width to less than 20 inches.    In the Flour Mill Building, the exit door leading out to the wooden stairway was missing a platform when the door swings outward onto the step of the stairway.
Recent events (2)
  • · I (S) $2700
  • · Z (S) $3850

1910.23 D01 III

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 20, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,850 · Current $2,000 Reduced
29 CFR 1910.23(d)(1)(iii):     On stairways less than 44 inches wide having both sides open, one stair railing on each side.    In the Flour Mill Building, Mill Office Area,  the wooden stairway with four steps leading out the exit door was lacking a stair railing on the open left side descending and the steps were not of the same rise and run.
Recent events (2)
  • · I (S) $2000
  • · Z (S) $3850

1910.23 E06

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 20, 2012
Abate by
Sep 18, 2012
Penalty
Initial $3,850 · Current $0 Reduced
29 CFR 1910.23(e)(6):     All handrails and railings shall be provided with a clearance of not less than 3 inches between the handrail or railing and any other object.    In the Mill Building a Mill Operator was exposed to a fall hazard from the second floor wooden stairway leading down to the first floor due to the lack of adequate clearance from the stair railing and the stair structure.
Recent events (2)
  • · I (S) $0
  • · Z (S) $3850

1910.132 A

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 20, 2012
Abate by
Oct 2, 2012
Penalty
Initial $5,390 · Current $3,800 Reduced
29 CFR 1910.132(a):     Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.    On top of the flat roof Midds building an employee was exposed to a 20' fall hazard while on the roof checking the wheat level on the Midds bin and while moving over to the edge of the building to go down the portable metal ladder to the ground.
Recent events (2)
  • · I (S) $3800
  • · Z (S) $5390

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 20, 2012
Abate by
Sep 28, 2012
Penalty
Initial $3,850 · Current $2,700 Reduced
29 CFR 1910.147(c)(4)(i):     Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.   Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance.    In the Mix Building, the specific energy control procedure for the bagger which has electrical, 220 Volts AC and pneumatic 90 psi, energy sources had not been developed.
Recent events (2)
  • · I (S) $2700
  • · Z (S) $3850

1910.178 G02

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 20, 2012
Abate by
Aug 28, 2012
Penalty
Initial $2,100 · Current $1,500 Reduced
29 CFR 1910.178(g)(2):     Facilities shall be provided for flushing and neutralizing spilled electrolyte, for fire protection, for protecting charging apparatus from damage by trucks, and for adequate ventilation for dispersal of fumes from gassing batteries.    In the Mix Room on the 1st Floor an electrical equipment battery charger for a sit down forklift and power pallet jack truck was located on the floor and was subject to damage from the forklift truck and other vehicles operating in the area.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2100

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 20, 2012
Abate by
Sep 28, 2012
Penalty
Initial $3,500 · Current $2,400 Reduced
29 CFR 1910.212(a)(1):     Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.    In the Mix Building on the Second Floor an employee was exposed to a caught inbetween hazard while adding ingredients into an unguarded Hobart portable mixer.
Recent events (2)
  • · I (S) $2400
  • · Z (S) $3500

1910.212 A05

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 20, 2012
Abate by
Aug 27, 2012
Penalty
Initial $3,850 · Current $1,900 Reduced
29 CFR 1910.212(a)(5):     Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the blades shall be guarded. The guard shall have openings no larger than one-half (1/2) inch.    In the Mix Building on the 2nd Floor an employee was exposed to the fan blades of a circular floor fan due to the pulled away three inch opening from the fan guard from the fan frame.
Recent events (2)
  • · I (S) $1900
  • · Z (S) $3850

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 20, 2012
Abate by
Sep 28, 2012
Penalty
Initial $3,850 · Current $2,000 Reduced
29 CFR 1910.219(d)(1):     Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes.    In the Mill Building basement a Mill Operator was exposed to a pinch point hazard from an unguarded pulley to a motor for a screw conveyor.
Recent events (2)
  • · I (S) $2000
  • · Z (S) $3850

1910.272 G01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 20, 2012
Abate by
Sep 28, 2012
Penalty
Initial $3,500 · Current $2,000 Reduced
29 CFR 1910.272(g)(1)(i):     The employer shall issue a permit for entering bins, silos, or tanks unless the employer or the employer's representative (who would otherwise authorize the permit) is present during the entire operation. The permit shall certify that the precautions contained in this paragraph (1910.272(g)) have been implemented prior to employees entering bins, silos or tanks. The permit shall be kept on file until completion of the entry operations.    On or about June 13-14, 2012, a mill employee was cleaning out the remaining wheat in Bin #6 and Silo #1 and had not been issued a bin entry permit to enter the bin and silo or had the employer's representative present during the entire operation.
Recent events (2)
  • · I (S) $2000
  • · Z (S) $3500

1910.305 B02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 20, 2012
Penalty
Initial $2,310 · Current $1,100 Reduced
29 CFR 1910.305(b)(2)(i):     All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.    In the Mix Building next to the Bagging Operation a two receptacle electrical outlet 110 Volt AC was missing a faceplate.
Recent events (2)
  • · I (S) $1100
  • · Z (S) $2310

1910.305 G01 IV

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 20, 2012
Penalty
Initial $2,310 · Current $1,100 Reduced
29 CFR 1910.305(g)(1)(iv):     Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:     In the Mix Room a flexible cord for a mounted wall fan was wrapped aound the door frame and was plugged into a 110 Volt AC two receptacle electrical outlet and was subject to damage.
Recent events (2)
  • · I (S) $1100
  • · Z (S) $2310

1910.334 A02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 20, 2012
Abate by
Sep 4, 2012
Penalty
Initial $2,310 · Current $1,200 Reduced
29 CFR 1910.334(a)(2)(i):     Portable cord and plug connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord and plug connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated.    Inside the door where the concrete silo screw conveyor was located, an employee was exposed to an electric hazard when an extension cord set had almost all of its outer insulation peeled off exposing the internal insulated wiring from being run from inside the door to the outside, overhead and then dropped down into a pit where it was plugged into a portable sump pump.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2310

1910.219 E03 I

Repeat Gravity 5 1 instance 2 exposed
Issued
Aug 20, 2012
Abate by
Oct 2, 2012
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.219(e)(3)(i):     Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section.    In the Basement of the Flour Mill Building, a vertical belt with a spoked wheel approximately three feet off the floor to a height of approximately eight feet was not enclosed with a guard conforming to standards in paragraphs (m) and (o).    H. Nagel & Son Co. was previously cited  for a violation on this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 108190, citation number 1, item 6b, which was affirmed as a final order on December 23, 2011, with respect to the workplace located at 2641 Spring Grove Ave., Cincinnati, OH 45246.
Recent events (2)
  • · I (R) $3500
  • · Z (R) $7000

1910.37 B02

Other-than-serious 1 instance 2 exposed
Issued
Aug 20, 2012
Abate by
Sep 4, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2):     Each exit must be clearly visible and marked by a sign reading "Exit."    In the First Floor of the Mill building a double door located on the East side of the building leading to the outside was not identified with an exit sign.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.68 E01

Other-than-serious 1 instance 3 exposed
Issued
Aug 20, 2012
Abate by
Sep 4, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.68(e)(1):     Frequency. All manlifts shall be inspected by a competent designated person at intervals of not more than 30 days. Limit switches shall be checked weekly. Manlifts found to be unsafe shall not be operated until properly repaired.    The belt manlift in the Floor Mill building had not been inspected and certified on at least a monthly basis.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 G01

Other-than-serious 1 instance 10 exposed
Issued
Aug 20, 2012
Abate by
Sep 4, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1):     Where the employer has provided portable fire extinguishers for employee use in the workplace, the employer shall also provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting.    Employees were allowed to use portable fire extinguishers at the facility and had not been provided with an educational program to familarize employees with fire extinguisher use and the hazards of incipient stage fire fighting.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View H. Nagel & SON CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334503745.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.