Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PINNACLE MANUFACTURING, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PINNACLE MANUFACTURING, LLC in 512 WEST HENDERSON RD, BOAZ, AL 35957 (NAICS 332420). OSHA activity number 334546330.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pinnacle Manufacturing, LLC — free Get an email when a new federal OSHA severe-injury report for Pinnacle Manufacturing, LLC is published. One employer, no account, unsubscribe in one click.
Site address
512 WEST HENDERSON RD
City
BOAZ
State
AL
ZIP
35957
Mailing
512 WEST HENDERSON RD, BOAZ, AL 35957
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332420
Employees
119
Ownership type
A

7 citations on file for this inspection.

1910.23 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 5, 2012
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level:    (a)  On or about 05/29/2012 - Main plant, the stairs near the east wall leading out of the plant did not have a mid-rail installed.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.28 A12

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 5, 2012
Penalty
Initial $5,400 · Current $3,240 Reduced
29 CFR 1910.28(a)(12):  An access ladder or equivalent safe access was not provided:      (a) On or about 05/29/2012 - Employees did not have a safe means to access scaffolding.
Recent events (2)
  • — I (S) $3240
  • — Z (S) $5400

1910.29 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 5, 2012
Penalty
Initial $5,400 · Current $3,240 Reduced
29 CFR 1910.29(a)(3)(ii): The minimum platform width for any work level was less than 20 inches for mobile scaffolds (towers). Ladder stands will have a minimum step width of 16 inches:    (a)  On or about 05/29/2012 - Main plant, the mobile scaffolding system had a raised platform from which an employee was working from that was less than 8 inches in width.
Recent events (2)
  • — I (S) $3240
  • — Z (S) $5400

1910.29 A04 II

Serious Gravity 5 3 instances 2 exposed
Issued
Sep 5, 2012
Penalty
Initial $5,400 · Current $3,240 Reduced
29 CFR 1910.29(a)(4)(ii):  All scaffold casters were not provided with a positive wheel and/or swivel lock to prevent movement:    (a)  On or about 05/29/2012 - The scaffolding wheels did not have a means for locking to keep them from moving while employees were working from the mobile scaffold.
Recent events (2)
  • — I (S) $3240
  • — Z (S) $5400

1910.29 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2012
Penalty
Initial $5,400 · Current $3,240 Reduced
29 CFR 1910.29(b)(2): Scaffolds was not properly braced by cross braces and/or diagonal braces for securing vertical members together laterally. The cross braces were not of a length that will automatically square and align vertical members so the erected scaffold is always plumb, square, and rigid:    (a)  On or about 05/29/2012 - The mobile scaffolding system did not have cross bracing to keep it plumb and square.
Recent events (2)
  • — I (S) $3240
  • — Z (S) $5400

1910.37 B02

Serious Gravity 1 10 instances 7 exposed
Issued
Sep 5, 2012
Penalty
Initial $2,700 · Current $1,620 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":    (a)  On or about 05/29/2012 - Main Plant, 10 doors being used as exits were not marked with a sign indicating that they were exits.
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.254 D09 III

Serious Gravity 5 4 instances 4 exposed
Issued
Sep 5, 2012
Penalty
Initial $5,400 · Current $3,240 Reduced
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced:    (a)  On or about 05/29/2012 - Main Plant, welding leads for the Miller welders were damaged.
Recent events (2)
  • — I (S) $3240
  • — Z (S) $5400

View Pinnacle Manufacturing, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334546330.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.