OSHA Inspection: PROMAXIMA MANUFACTURING LTD.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PROMAXIMA MANUFACTURING LTD. in 5310 ASHBROOK DRIVE, HOUSTON, TX 77081 (NAICS 339920). OSHA activity number 334594751.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Promaxima Manufacturing LTD. — free Get an email when a new federal OSHA severe-injury report for Promaxima Manufacturing LTD. is published. One employer, no account, unsubscribe in one click.
Site address
5310 ASHBROOK DRIVE
City
HOUSTON
State
TX
ZIP
77081
Mailing
5310 ASHBROOK DRIVE, HOUSTON, TX 77081
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339920
Employees
200
Ownership type
A

12 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 3 instances 3 exposed
Issued
Nov 19, 2012
Abate by
Apr 30, 2014
Penalty
Initial $6,300 · Current $3,000 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a) Cutting department, North side - Energy control procedures had not been developed for the eastern most metal band saw.  Employees are exposed to caught-in hazards when changing the blades.    b) Cutting department, North side - Energy control procedures had not been developed for the middle metal band saw.  Employees are exposed to caught-in hazards when changing the blades.    c) Cutting department, North side - Energy control procedures had not been developed for the western most metal band saw.  Employees are exposed to caught-in hazards when changing the blades.    d) Cutting department, East side - Energy control prodedures had not been developed for the Metal Muncher shear model number MM-70, serial nubmer 035150298.  Employees are exposed to caught-in hazards when changing the blade.
Recent events (3)
  • — F (S) $3000
  • — C (S) $6300
  • — Z (S) $6300

1910.147 C05 I

Serious Gravity 10 4 instances 3 exposed
Issued
Nov 19, 2012
Abate by
Apr 30, 2014
Penalty
Initial $6,300 · Current $3,000 Reduced
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:    a) Cutting department, North side - Employees, who are exposed to caught-in hazards when changing blades on the eastern most metal band saw, were not provided with locks or tags.    b) Cutting department, North side - Employees, who are exposed to caught-in hazards when changing blades on the middle metal band saw, were not provided with locks or tags.    c) Cutting department, North side - Employees, who are exposed to caught-in hazards when changing blades on the western most metal band saw, were not provided with locks or tags.     d) Cutting department, East side - Employees, who are exposed to caught-in hazards when changing the blade of the Metal Muncher shear model number MM-70, serial number 035150298, were not provided with locks or tags.
Recent events (3)
  • — F (S) $3000
  • — C (S) $6300
  • — Z (S) $6300

1910.147 D04 I

Serious Gravity 10 4 instances 3 exposed
Issued
Nov 19, 2012
Abate by
Dec 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:      a) Cutting department, North side - A lock was not affixed to the electrical disconnect when employees were changing blades on the eastern most metal band saw, exposing employees to caught-in hazards.       b) Cutting department, North side - A lock was not affixed to the electrical disconnect when employees were changing blades on the middle metal band saw, exposing employees to caught-in hazards.     c) Cutting department, North side - A lock was not affixed to the electrical disconnect when employees were changing blades on the western most metal band saw, exposing employees to caught-in hazards.      d) Cutting department, East side - A lock was not affixed to the electrical disconnect when employees were changing the blade of the Metal Muncher shear model number MM-70, serial number 035150298, exppsoing employees to caught-in hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.178 L01 I

Other-than-serious 2 instances 2 exposed
Issued
Nov 19, 2012
Abate by
Apr 30, 2014
Penalty
Initial $4,500 · Current $2,175 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a)  At the site - Employees were operating TCM forklift trucks and were not certified to do so, exposing employees to struck-by and/or crushing hazards.
Recent events (3)
  • — F (O) $2175
  • — C (S) $4500
  • — Z (S) $4500

1910.212 A03 II

Serious Gravity 10 3 instances 3 exposed
Issued
Nov 19, 2012
Abate by
Apr 30, 2014
Penalty
Initial $6,300 · Current $3,000 Reduced
29 CFR 1910.212(a)(3)(ii): The  point of operation of machines whose operation exposed an employee to injury was not guarded:    a) Inside cutting area, east side - At the point of operation on the Machine #1 metal band saw approximately 7 inches of the unused portion of the blade was not guarded, exposing employees to caught-in/amputation hazards.    b) Inside cutting area, between east and west machine - At the point of operation on the Machine #2 metal band saw approximately 7 inches of the unused portion of the blade was not guarded, exposing employees to caught-in/amputation hazards.    c) Inside cutting area, west side - At the point of operation on the Machine #3 metal band saw approximately 7 inches of the unused portion of the blade was not guarded, exposing employees to caught-in/amputation hazards.
Recent events (3)
  • — F (S) $3000
  • — C (S) $6300
  • — Z (S) $6300

1910.212 A05

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Nov 19, 2012
Abate by
Nov 21, 2012
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level:    a)  Near the abrasive blasting operation -  The blades of a MAXXIAR indoor shop fan (ID BF24TF2N1 MD BVM-MXX01) were not guarded, exposing an employee to caught-in/amputation hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $6300
  • — Z (S) $6300

1910.212 B

Other-than-serious 2 instances 2 exposed
Issued
Nov 19, 2012
Abate by
Apr 30, 2014
Penalty
Initial $3,600 · Current $2,175 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    a) Metal fabrication shop, north end - A vertical grinder was not secured in place, exposing employees to potential crushing hazards.      b) Metal fabrication shop, cental area - A vertical grinder was not secured in place, exposing employees to potential crushing hazards.
Recent events (3)
  • — F (O) $2175
  • — C (S) $3600
  • — Z (S) $3600

1910.243 C01

Serious Gravity 5 14 instances 10 exposed
Issued
Nov 19, 2012
Abate by
Apr 30, 2014
Penalty
Initial $5,400 · Current $3,000 Reduced
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4):    a)  Metal fabrication shop - On 14 portable DeWalt angle grinders, a safety guard did not cover the spindle end and flange projections, exposing the employes to caught-in and struck-by hazards.
Recent events (3)
  • — F (S) $3000
  • — C (S) $5400
  • — Z (S) $5400

1910.253 B02 II

Other-than-serious 1 instance 4 exposed
Issued
Nov 19, 2012
Abate by
Apr 30, 2014
Penalty
Initial $4,500 · Current $2,175 Reduced
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:    a) Inside the fabrication shop - Two Argon cylinders located at a welders workstation in a high foot traffic area were not secured, exposing employees to potential struck-by hazards.    b) Outside the powder coating area - A group of 17 cylinders behind the trash bin area were not secured, exposing employees to potential struck-by hazards.
Recent events (3)
  • — F (O) $2175
  • — C (S) $4500
  • — Z (S) $4500

1910.253 B04 I

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Nov 19, 2012
Abate by
Nov 21, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(i):  Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire:    a)  Outside the abrasive/paint/curing building - Oxygen cylinders were stored in and around acteylene and other compressed gas cylinders behind the trash bins, exposing employees to explosion and fire hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.303 G01 I A

Other-than-serious 3 instances 1 exposed
Issued
Nov 19, 2012
Abate by
Apr 30, 2014
Penalty
Initial $4,500 · Current $2,175 Reduced
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening whwere they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:    a) Inside the cutting room, north wall - Three electrical panels were blocked by an out-of-service industrial drill press.  This condition exposed employees to electircal fires and electrical shock.      b) Inside the metal fabrication shop, west wall - The electrical panel was blocked by scrap material.  This condition exposed employees to electrical fires and electrical shock.      c) Inside metal fabrication shop, southeast corner near bay door -  Four electrical panels were blocked by service material.  This condition exposed employees to electrical fires and elctrical shock.
Recent events (3)
  • — F (O) $2175
  • — C (S) $4500
  • — Z (S) $4500

1910.146 C01

Other-than-serious 1 instance 1 exposed
Issued
Nov 19, 2012
Abate by
Apr 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:    a)  On the east side of the fabrication shop - The employer had not identified possible confined spaces which employees enter at least twice a year.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Promaxima Manufacturing LTD.'s full OSHA safety record →