OSHA Inspection: TROPEX GARDENS, CO. LTD

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TROPEX GARDENS, CO. LTD in GARAPAN ELEMENTARY SCHOOL BLDG. E SECOND FLOOR ADDITION OF FIVE CLASSROOMS PROJECT GARAPAN, SAIPAN, MP 96950 (NAICS 236220). OSHA activity number 334619640.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tropex Gardens, CO. LTD — free Get an email when a new federal OSHA severe-injury report for Tropex Gardens, CO. LTD is published. One employer, no account, unsubscribe in one click.
Site address
GARAPAN ELEMENTARY SCHOOL BLDG. E SECOND FLOOR ADDITION OF FIVE CLASSROOMS PROJECT GARAPAN
City
SAIPAN
State
MP
ZIP
96950
Mailing
PO BOX 502473 CHALAN KANOA, SAIPAN, MP 96950
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
25
Ownership type
A

4 citations on file for this inspection.

1926.404 F06

Serious Gravity 1 2 instances 5 exposed
Issued
Aug 8, 2012
Abate by
Aug 13, 2012
Penalty
Initial $1,785 · Current $1,785
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, and enclosures was not permanent and continuous:    (a) On the east side of the second level addition on or about June 11, 2012, and at times prior thereto there was no grounding pin on a plug for a 110 VAC floor standing metal fan.      (b) On the west side of the second level addition on or about June 11, 2012, and at times prior thereto there was no grounding of the metal fixture that contained two, 110 VAC four foot long florescent light bulbs.  The fixture that was mounted to a wooden stand, and the top of the fixture was 64 inches from the floor.  The grounding wire was cut off where the cable entered the fixture.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $1785

1926.405 A02 II E

Serious Gravity 1 1 instance 5 exposed
Issued
Aug 8, 2012
Abate by
Aug 13, 2012
Penalty
Initial $1,785 · Current $0 Reduced
29 CFR 1926.405(a)(2)(ii)(E): All lamps for general illumination were not protected from accidental contact or breakage:    (a) On the west side of the second level addition on or about June 11, 2012, and at times prior thereto two, four foot long florescent light bulbs were not protected from accidental contact or breakage as there was no cover or screen over the bulbs.  The bulbs were in a fixture that was mounted to a wooden stand.  The top of the fixture was 64 inches from the floor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1785

1926.405 B02

Other-than-serious 1 instance 5 exposed
Issued
Aug 8, 2012
Abate by
Aug 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers. When metal covers are used, they were not grounded. In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass were not provided with bushings designed for the purpose or they did not have smooth, well-rounded surfaces on which the cords may bear:    (a) On the west side of the second level addition on or about June 11, 2012, and at times prior thereto there was no bushing or well rounded surface where the power cord enter the metal fixture that contained two, 110 VAC four foot long florescent light bulbs.  The fixture that was mounted to a wooden stand, and the top of the fixture was 64 inches from the floor.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.600 A03 II

Other-than-serious 1 instance 1 exposed
Issued
Aug 8, 2012
Abate by
Aug 13, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.600(a)(3)(ii): Whenever the equipment was parked, the parking brake was not set:    (a) On the east side ground level of the project on or about June 11, 2012, and at times prior thereto the parking brake was not set on Caterpillar backhoe, model number 420 D, serial number BJ50563.  No operator was in site.  The motor was off.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334619640.