Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OVERHEAD SOLUTIONS INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of OVERHEAD SOLUTIONS INC in 1228 WIRTZ AVENUE, GREEN BAY, WI 54304 (NAICS 238160). OSHA activity number 334652781.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Overhead Solutions INC — free Get an email when a new federal OSHA severe-injury report for Overhead Solutions INC is published. One employer, no account, unsubscribe in one click.
Site address
1228 WIRTZ AVENUE
City
GREEN BAY
State
WI
ZIP
54304
Mailing
P.O. BOX 12774, GREEN BAY, WI 54307
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.416 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 19, 2012
Abate by
Nov 1, 2012
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.416(a)(1):     Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:      a)  On 06-12-12, employees were performing roofing work within three (3) feet of a less than 300V residential electrical service feed without utilizing electrical shock protection.    b)  On 06-12-12, employees who were performing roofing work were accessing the roof work surface within (3) feet of a less than 300V residential electrical service feed without utilizing electrical shock protection.    Abatement Certification and Abatement Documentation required
Recent events (3)
  • — F (S) $2000
  • — C (S) $2000
  • — Z (S) $2000

1926.451 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 19, 2012
Abate by
Nov 1, 2012
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.451(f)(6):     Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6):    On 06-12-12, employees who were performing roofing work were utilizing a ladder jack scaffold which was positioned within three (3) feet of a less than 300V residential electrical service feed.      Abatement Certification and Abatement Documentation required
Recent events (3)
  • — F (S) $0
  • — C (S) $2000
  • — Z (S) $2000

1926.100 A

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 19, 2012
Abate by
Nov 1, 2012
Penalty
Initial $4,000 · Current $0 Reduced
29 CFR 1926.100(a):     Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:      On 06-12-12, employees who were performing roofing work were positioned underneath and around a less than 300V residential electrical service feed without utilizing head protection.    OVERHEAD SOLUTIONS INC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUUIVALENT STANDARD 1926.100(a) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 315288720 (OIS NUMBER 89446), CITATION NUMBER 01, ITEM 001(a), AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 9, 2011 WITH RESPECT TO A WORKPLACE LOCATED AT 2410 SOUTH BERRY DRIVE; APPLETON, WI  54915.      Abatement Certification and Abatement Documentation required
Recent events (3)
  • — F (S) $0
  • — C (R) $4000
  • — Z (R) $4000

1926.501 B13

Serious Gravity 5 2 instances 4 exposed
Issued
Sep 19, 2012
Abate by
Nov 1, 2012
Penalty
Initial $10,000 · Current $1,500 Reduced
29 CFR 1926.501(b)(13):     Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:      a)  On 06-12-12, three employees were working on a main house roof surface with a 7:12 pitch and an eave edge greater than ten (10) feet above compacted surface without utilizing fall protection equipment.    b)  On 06-12-12, one employee was working on a house addition roof surface with a 7:12 pitch and an eave edge nine (9) feet above compacted surface without utilizing fall protection equipment.      OVERHEAD SOLUTIONS INC WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUUIVALENT STANDARD 1926.501(b)13 WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 315288092 (OIS NUMBER 89398), CITATION NUMBER 01, ITEM 002, AND WAS AFFIRMED AS A FINAL ORDER ON JULY 28, 2011 WITH RESPECT TO A WORKPLACE LOCATED AT 1127 W COMMERCIAL ST; APPLETON, WI  54914.      Abatement Certification and Abatement Documentation required
Recent events (3)
  • — F (S) $1500
  • — C (R) $10000
  • — Z (R) $10000

View Overhead Solutions INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334652781.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.