HOUSTON, TX —
OSHA Inspection: V & R DRYWALL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of V & R DRYWALL, INC. in 6223 E. SAM HOUSTON PKWY E., HOUSTON, TX 77049 (NAICS 236220). OSHA activity number 334665981.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- V & R DRYWALL, INC.
- Site address
- 6223 E. SAM HOUSTON PKWY E.
- City
- HOUSTON
- State
- TX
- ZIP
- 77049
- Mailing
- 6064 LUCKETT CT, EL PASO, TX 79932
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01 I
- Issued
- Jul 25, 2012
- Abate by
- Aug 8, 2012
- Penalty
- Initial $6,300 · Current $6,300
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. The employer does not ensure that each scaffold platform is fully decked between the platform and uprights so that no more than a 1 inch gap remains. This violation was observed on June 11, 2012, on the east side of a newly built structure where employees were exposed to 12 and 18 foot fall hazards while installing metal lath from a set of fabricated frame scaffolds that was planked half of the width leaving a gap of approximately 28 inches.
Recent events (2)
- — I (S) $6300
- — Z (S) $6300
1926.451 E01
- Issued
- Jul 25, 2012
- Abate by
- Aug 8, 2012
- Penalty
- Initial $4,500 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. The employer does not ensure that scaffold platforms more than 2 feet above or below a point of access are provided with a ladder or other means of access. This violation was observed on or about June 11, 2012, on the east side of a newly built structure where employees were exposed to a 12 and 18 foot fall hazard while accessing a set of fabricated frame scaffolds that did not have a ladder or other means of safe access.
Recent events (2)
- — I (S) $0
- — Z (S) $4500
1926.452 C02
- Issued
- Jul 25, 2012
- Abate by
- Aug 8, 2012
- Penalty
- Initial $6,300 · Current $0 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: The employer does not ensure that scaffold frames are braced by cross, horizontal, or diagonal braces. This violation was observed on June 11, 2012, on the east side of a newly built structure where employees were exposed to 12 and 18 foot fall hazards while installing metal lath from a set of fabricated frame scaffolds that did not have braces installed on all sets.
Recent events (2)
- — I (S) $0
- — Z (S) $6300
1926.416 E01
- Issued
- Jul 25, 2012
- Abate by
- Aug 8, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: The employer does not ensure that worn or frayed cords are not used. This violation was occurred on or about June 11, 2012, or times prior thereto, where employees on the east side of the newly built structure were using a Chicago Electric 1/2 inch drill that had a frayed electrical cord.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at V & R Drywall, INC.