EMMETT, ID —
OSHA Inspection: BROWN BROTHERS CONSTRUCTION COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BROWN BROTHERS CONSTRUCTION COMPANY, INC. in 1075 CHERRY LANE, EMMETT, ID 83617 (NAICS 113310). OSHA activity number 334669595.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BROWN BROTHERS CONSTRUCTION COMPANY, INC.
- Site address
- 1075 CHERRY LANE
- City
- EMMETT
- State
- ID
- ZIP
- 83617
- Mailing
- PO BOX 125, EMMETT, ID 83617
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 113310
- Employees
- 21
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.110 D10
- Issued
- Nov 9, 2012
- Abate by
- Nov 23, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.110(d)(10): LP-Gas systems were exposed to damage from vehicular traffic, precautions against such damage were not taken. a) At the wash rack at the shop, on June 12, 2012 and at times prior thereto, the 250 gallon LP gas tank end was unprotected at the edge of the concrete apron. Note: Abatement certifiaction is required.
Recent events (1)
- — Z (O) $0
1910.215 A04
- Issued
- Nov 9, 2012
- Abate by
- Nov 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): On offhand grinding machines, work rests were not kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest: a) In the shop, on June 12, 2012, and at times prior thereto, the work rest on the Black and blue bench grinder was missing. b) In the shop, on June 12, 2012, and at times prior thereto, the work rest on the Jet bench grinder was 3/8 on an inch. Note: Abatement certifiaction is required.
Recent events (1)
- — Z (O) $0
1910.215 B09
- Issued
- Nov 9, 2012
- Abate by
- Nov 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Safety guards were not adjusted so that the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceeded one-fourth inch: a) In the Shop, on June 12, 2012, and at times prior therto, the tongue guard on the black and blue bench grinder was missing. b) In the Shop, on June 12, 2012, and at times prior thereto, the tongue guard on the Marc bench grinder was 1/2 inch. c) Iin the Shop, on June 12, 2012, and at times prior thereto, the tongue guard on the Jet bench grinder was 5/8 inch. Note: Abatement certification is required.
Recent events (1)
- — Z (O) $0
1910.244 A01 II
- Issued
- Nov 9, 2012
- Abate by
- Nov 23, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.244(a)(1)(ii): The rated load was not legibly and permanently marked in a prominent location on the jack by casting, stamping, or other suitable means: 1) At the shop, on June 12, 2012, and at times prior thereto, weight ratings on three bottle jacks were not legibly and permanently marked. Note: Abatement certification is required.
Recent events (1)
- — Z (O) $0
1910.244 A02 VI A
- Issued
- Nov 9, 2012
- Abate by
- Nov 23, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.244(a)(2)(vi)(a): Portable jacks used in the shop were not inspected once every six months when they were used constantly or intermittently: a) At the Shop, on June 12, 2012, and at times prior thereto, all the jacks were not inspected. Note: Abatement certification is required.
Recent events (1)
- — Z (O) $0
1910.253 B04 III
- Issued
- Nov 9, 2012
- Abate by
- Nov 23, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a) In the Shop: on June 12, 2012, and at times prior thereto, acetylene and liquid propane gas cylinders were stored next to oxygen cylinders. Note: Abatement certification is required.
Recent events (1)
- — Z (O) $0
1910.305 G02 III
- Issued
- Nov 9, 2012
- Abate by
- Nov 20, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided to prevent pull from being directly transmitted to joints or terminal screws: a) In the Shop, On or about June 12, 2012 and at times prior therto, the power supply cord on the black and blue bench grinder lacked strain relief. Note: Abatement certification is required.
Recent events (1)
- — Z (O) $0
More inspections at Brown Brothers Construction Company, INC.
View Brown Brothers Construction Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 113310)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334669595.