Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: TRITZ PALLETS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TRITZ PALLETS in 7215 SW TOPEKA BLVD., TOPEKA, KS 66619 (NAICS 321920). OSHA activity number 334681392.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tritz Pallets for free Get an email when a new federal OSHA severe-injury report for Tritz Pallets is published. One employer, no account, unsubscribe in one click.
Establishment
TRITZ PALLETS
Site address
7215 SW TOPEKA BLVD.
City
TOPEKA
State
KS
ZIP
66619
Mailing
7215 SW TOPEKA BLVD., TOPEKA, KS 66619
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
16
Ownership type
A

5 citations on file for this inspection.

1910.178 F02

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 12, 2012
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.178(f)(2):  The storage and handling of liquefied petroleum gas fuel was not in accordance with NFPA No. 58-1969, Storage and Handling of Liquefied Petroleum Gases. Section 6.21.3.4(B): Fuel containers shall be mounted to prevent jarring loose and slipping or rotating, and the fastening shall be designed and constructed to withstand, without permanent visible deformation, static loading in any direction equal to four times the weight of the container filled with fuel:    At 7215 SW Topeka Blvd, Bldg 3A in the warehouse, forklift #366's propane tank was not secured, exposing employees to an explosion and fire hazard.
Recent events (2)
  • · I (S) $840
  • · Z (S) $1200

1910.178 L01 II

Serious Gravity 5 1 instance 16 exposed
Issued
Oct 12, 2012
Abate by
Nov 2, 2012
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a forklift:    At 7215 SW Topeka Blvd, Bldg 3A in the warehouse, the employer failed to ensure that forklift operators were properly trained before operating a forklift, exposing employees to potential struck by injuries.
Recent events (2)
  • · I (S) $1120
  • · Z (S) $1600

1910.303 B02

Serious Gravity 1 2 instances 16 exposed
Issued
Oct 12, 2012
Abate by
Nov 2, 2012
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.303(b)(2):     Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    At 7215 SW Topeka Blvd, Topeka, KS, building 3A in the warehouse, electrical equipment was not being used in accordance with its design, exposing employees to potential shock and fire hazard in the following instances:    1) Electrical romex was being used to power electrical fixtures on the east wall without being enclused in conduit to protect it's outer sheathing.    2) Electrical romex wiring was spun around a 2"x4" on the east wall.    3) Light fixture was not secured and was being used as a portable light.
Recent events (2)
  • · I (S) $840
  • · Z (S) $1200

1910.305 J01 I

Serious Gravity 1 1 instance 4 exposed
Issued
Oct 12, 2012
Abate by
Nov 2, 2012
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.305(j)(1)(i):     Fixtures, lampholders, lamps, rosettes, and receptacles located had live parts normally exposed to employee contact:    At 7215 SW Topeka Blvd, Topeka, KS, building 3A in the warehouse on the east wall, electrical equipment had exposed contacts, exposing employees to potential shcok hazards in the following instances:    1) A single-bulb light fixture located on the east wall of the warehouse was missing a light bulb and was wired for operation.    2) A light switch in the employee break area did not have a cover plate.    3) An electrical outlet in the employee break area did not have a cover plate.
Recent events (2)
  • · I (S) $840
  • · Z (S) $1200

1910.178 A06

Other-than-serious 1 instance 2 exposed
Issued
Oct 12, 2012
Abate by
Nov 2, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates and markings were in place:    At 7215 SW Topeka Blvd, Bldg 3A, Topeka, KS in the warehouse, forklifts were missing labels on the controls on Forklift #380 and #982, exposing employees to a struck by hazard.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Tritz Pallets's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334681392.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.