OSHA Inspection: H&A PLASTERING, LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of H&A PLASTERING, LLC in 3401 E. FAIRVIEW AVENUE, MERIDIAN, ID 83642 (NAICS 238140). OSHA activity number 334681798.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch H&A Plastering, LLC — free Get an email when a new federal OSHA severe-injury report for H&A Plastering, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
H&A PLASTERING, LLC
Site address
3401 E. FAIRVIEW AVENUE
City
MERIDIAN
State
ID
ZIP
83642
Mailing
P.O. BOX 8, NAMPA, ID 83653
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 26, 2012
Penalty
Initial $1,700 · Current $853 Reduced
29 CFR 1926.451(b)(1):     Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):    a) North and west facade of the northwest corner, 2nd, 3rd and 4th levels; On or about June 13, 2012 and at times prior thereto, employees performing stucco work were working on 3 foot wide tubular welded frame scaffold that had sections that were not fully planked. Only two planks were used in lieu of the three that were needed.     Note: Abatement certification is Not required for this item.
Recent events (2)
  • — I (S) $853
  • — Z (S) $1700

1926.451 B03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(3)(ii):     The maximum distance from the face for plastering and lathing operations exceeded 18 inches (46 cm):    a) West facade at the south end of the 2nd, 3rd and 4th levels; On or about June 13, 2012 and at times prior thereto, employees performing stucco work were working on 3 foot wide tubular welded frame scaffold that had sections where the platform was 22 inches away from the face of the structure.      Note: Abatement certification is Not required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G04

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4):     Guardrail systems installed to meet the requirements of this section did not comply with the provisions listed in subparagraphs (i) through (xv) of this paragraph:    a) North and west facade of the northwest corner, 2nd, 3rd and 4th levels; On or about June 13, 2012 and at times prior thereto, employees performing stucco work were working on 3 foot wide tubular welded frame scaffold that had sections where the top rail or mid rail were missing.      Note: Abatement certification is Not required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 26, 2012
Penalty
Initial $1,445 · Current $720 Reduced
29 CFR 1926.451(e)(1):     When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcture, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.    a) North and west facade of the northwest corner, 1st, 2nd, 3rd and 4th levels; On or about June 13, 2012 and at times prior thereto, employees were not provided with safe access on/off of the welded frame scaffold that they were performing stucco work from. The employees were crawling across from and adjacent roof top and/or climbing the end frames.    Note: Abatement certification is Not required for this item.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1445

View H&A Plastering, LLC's full OSHA safety record →