On , OSHA opened a planned safety inspection of EA CONSTRUCTION in 1130 COLUMBIA RD NW, WASHINGTON, DC 20010 (NAICS 236118). OSHA activity number 334682994.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EA CONSTRUCTION
- Site address
- 1130 COLUMBIA RD NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20010
- Mailing
- 20900 SANDSTON SQ, STERLING, VA 20165
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.403 B02
- Issued
- Aug 21, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.403(b)(2): Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification. a) Second Floor - An unapproved, power strip/tap with six outlets, was used by employees to provide power to electrical power tools either directly or through portable extension cords.
Recent events (1)
- — Z (S) $1200
1926.404 B01 II
- Issued
- Aug 21, 2012
- Abate by
- Sep 5, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection. a) Throughout the Site - Receptacles outlets were not protected with ground fault circuit interrupters. Workers had used the outlets to provide power to their electrical power tools; e.g., Dewalt 304P and Milwaukee reciprocating saws.
Recent events (1)
- — Z (S) $0
1926.405 B02
- Issued
- Aug 21, 2012
- Abate by
- Sep 5, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: a) Throughout the Site - Employees were plugged into energized outlets were not equipped with a face plate to guard from accidental contact of the energized conductors.
Recent events (1)
- — Z (S) $1200
1926.501 B13
- Issued
- Aug 21, 2012
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b) a) Rear/Southside of the Building - Employee were not protected by a personal fall arrest system while working on a low-slope roof exposing him to a 40 foot fall to ground level. b) 1st, 2nd & 3rd Floors - Employees were exposed to a fall hazard while using the stairs or accessing them; the lower area of the stairs and the actual stair area are not guarded by a rail system that would prevent employees from falling to the lower level nor have hand rails been installed. c) 1st, 2nd & 3rd Floors - Employees were exposed to open floor openings on the first, second and third floor where a future chimney would be installed.
Recent events (1)
- — Z (S) $2800
1926.1053 B04
- Issued
- Aug 21, 2012
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Third Floor South/Rear Area of Site - Employees were using a step ladder in the closed position to access the roof area off the third flloor deck area. Employees were exposed to a fall from elevation of approximately 11ft to the lower level.
Recent events (1)
- — Z (S) $1200
More inspections at EA Construction
View EA Construction's full OSHA safety record →
More inspections in this industry (NAICS 236118)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334682994.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.