Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EA CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EA CONSTRUCTION in 1130 COLUMBIA RD NW, WASHINGTON, DC 20010 (NAICS 236118). OSHA activity number 334682994.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch EA Construction — free Get an email when a new federal OSHA severe-injury report for EA Construction is published. One employer, no account, unsubscribe in one click.
Establishment
EA CONSTRUCTION
Site address
1130 COLUMBIA RD NW
City
WASHINGTON
State
DC
ZIP
20010
Mailing
20900 SANDSTON SQ, STERLING, VA 20165
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.403 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 21, 2012
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.403(b)(2): Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.    a)  Second Floor - An unapproved, power strip/tap with six outlets, was used by employees to provide power to electrical power tools either directly or through portable extension cords.
Recent events (1)
  • — Z (S) $1200

1926.404 B01 II

Serious Gravity 5 3 instances 3 exposed
Issued
Aug 21, 2012
Abate by
Sep 5, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection.    a)  Throughout the Site - Receptacles outlets were not protected with ground fault circuit interrupters.  Workers had used the outlets to provide power to their electrical power tools; e.g., Dewalt 304P and Milwaukee reciprocating saws.
Recent events (1)
  • — Z (S) $0

1926.405 B02

Serious Gravity 1 4 instances 3 exposed
Issued
Aug 21, 2012
Abate by
Sep 5, 2012
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:    a)  Throughout the Site - Employees were plugged into energized outlets were not equipped with a face plate to guard from accidental contact of the energized conductors.
Recent events (1)
  • — Z (S) $1200

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 21, 2012
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(13):  Employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph (b)    a)  Rear/Southside of the Building - Employee were not protected by a personal fall arrest system while working on a low-slope roof exposing him to a 40 foot fall to ground level.    b)  1st, 2nd & 3rd Floors - Employees were exposed to a fall hazard while using the stairs or accessing them; the lower area of the stairs and the actual stair area are not guarded by a rail system that would prevent employees from falling to the lower level nor have hand rails been installed.     c)  1st, 2nd & 3rd Floors - Employees were exposed to open floor openings on the first, second and third floor where a future chimney would be installed.
Recent events (1)
  • — Z (S) $2800

1926.1053 B04

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 21, 2012
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.1053(b)(4):  Ladder(s) were used for purposes other than the purpose for which they were designed:    a)  Third Floor South/Rear Area of Site - Employees were using a step ladder in the closed position to access the roof area off the third flloor deck area.  Employees were exposed to a fall from elevation of approximately 11ft to the lower level.
Recent events (1)
  • — Z (S) $1200

View EA Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334682994.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.