Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SPD SOLUTIONS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SPD SOLUTIONS, INC. in 2381 CIRCUIT WAY, BROOKSVILLE, FL 34604 (NAICS 332812). OSHA activity number 334759610.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch SPD Solutions, INC. — free Get an email when a new federal OSHA severe-injury report for SPD Solutions, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SPD SOLUTIONS, INC.
Site address
2381 CIRCUIT WAY
City
BROOKSVILLE
State
FL
ZIP
34604
Mailing
2381 CIRCUIT WAY, BROOKSVILLE, FL 34604
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
8
Ownership type
A

4 citations on file for this inspection.

1910.107 H12

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2012
Abate by
Apr 30, 2013
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.107(h)(12): Electrostatic spray area(s) were not provided with automatic sprinkler protection or other approved automatic extinguishing equipment:    a) For the SPD Solutions facility at 2381 Circuit Way, Brooksville, FL 34604, as observed on or about 06/19/2012, powder coating of metallic parts took place in a powder coating booth. There were no sprinklers or any other extinguishing means in the booth. Employees were exposed to fire hazards from the combustible powder coating dust due to lack of automatic extinguishment equipment.
Recent events (4)
  • — I $3400
  • — Z $8000
  • — I (S) $960

1910.107 L02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2012
Abate by
Sep 12, 2012
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.107(l)(2)(i): All non-deposited air-suspended powder was not safely removed via exhaust ducts to the powder recovery cyclone or receptacle:    a) For the SPD Solutions facility at 2381 Circuit Way, Brooksville, FL 34604, as observed on or about 06/19/2012, combustible class II powder coating dust was emitted from the powder coating booth to the building behind and around the booth. The dust had accumulated up to ? inch deep around the booth and resulted in a potential dust dispersion concentration of 40-130 grams per cubic meter. The minimum explosive concentration for the powder coating dust was listed to range between 15 and 50 grams per cubic meter according to the manufacturers material safety data sheets. Employees working in the room containing the powder coating booth were exposed to fire or explosion hazards associated with the emission and accumulation of combustible powder coating dust in the building.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.107 L04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2012
Abate by
Sep 12, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.107(l)(4)(i): All areas were not kept free of the accumulation of powder coating dust:    a) For the SPD Solutions facility at 2381 Circuit Way, Brooksville, FL 34604, as observed on or about 06/19/2012, combustible class II powder coating dust had accumulated up to ? inch deep around the booth and resulted in a potential dust dispersion concentration of 40-130 grams per cubic meter in the powder coating room. The minimum explosive concentration for the powder coating dust was listed to range between 15 and 50 grams per cubic meter according to the manufacturers material safety data sheets. Employees working in the room containing the powder coating booth were exposed to fire or explosion hazards associated with the accumulation of combustible powder coating dust around the booth.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 7 exposed
Issued
Sep 5, 2012
Abate by
Sep 12, 2012
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    a) For the SPD Solutions facility at 2381 Circuit Way, Brooksville, FL 34604, as observed on or about 06/19/2012, the plug on a 220V Millermatic 251 MIG Arc welder used at the facility had pulled away from its insulation resulting is tension being transmitted to the plug wire connectors. This resulted in an electric shock or fire hazard to employees plugging in or operating the equipment.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

View SPD Solutions, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334759610.