Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: NATIONAL BEEF

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NATIONAL BEEF in 2000 E. TRAIL, DODGE CITY, KS 67801 (NAICS 311611). OSHA activity number 334803392.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch National Beef for free Get an email when a new federal OSHA severe-injury report for National Beef is published. One employer, no account, unsubscribe in one click.
Establishment
NATIONAL BEEF
Site address
2000 E. TRAIL
City
DODGE CITY
State
KS
ZIP
67801
Mailing
2000 E. TRAIL, DODGE CITY, KS 67801
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311611
Employees
3000
Ownership type
Private (A)

7 citations on file for this inspection.

1910.36 G02

Serious Gravity 10 5 instances 25 exposed
Issued
Oct 18, 2012
Abate by
Nov 8, 2012
Penalty
Initial $7,000 · Current $5,000 Reduced
29 CFR 1910.36(g)(2): An exit access must be at least 28 inches (71.1 cm) wide at all points. Where there is only one exit access leading to an exit or exit discharge, the width of the exit and exit discharge must be at least equal to the width of the exit access.    In the event of an emergency evacuation, the employees were exposed to hazards such as related to a Fire, and Anhydrous Ammonia leaks. The employees were exposed in that sufficient space for an exit discharge was not provided:    a)On the Fab-floor, the Shank saw operator(s) (Saw #17) was allowed approximately 16 inches for egress.    29 CFR 1903.19(d)(1) Requires certification and documentation that the abatement of the above violation is complete.        b)On the Fab-floor, an employee working below a staircase (Between BT4 and BT5) did not have an egress.    c)On the Fab-floor, employees (approximately 19 employees) working in back-pack-off were allowed approximately 17 inches for an egress.    d)On the Fab-floor, the Wing saw operator (Saw #3) was allowed approximately 16 inches for egress, from the stair to the combo box.    e)On the Fab-floor, an employee  working below a staircase (Between BT2 and BT3) was allowed approximately 10 inches on one side and 16 Inches on another side.    29 CFR 1903.19(c)(2) abatement of the above violation was verified at time of inspection, no certification is required.
Recent events (2)
  • · I (S) $5000
  • · Z (S) $7000

1910.151 C

Deleted Serious Gravity 10 2 instances 4 exposed
Issued
Oct 18, 2012
Abate by
Nov 8, 2012
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.    Employees were exposed to acid burns and serious eye injuries while spraying Delasan MP, containing Peroxyacetic Acid and Acetic Acid with a pressurized container. The employees were exposed in that an eye wash station was not provided in the following areas:    a) In Hot Box # 1.     b) In the Hamburger area.
Recent events (2)
  • · I (S) $0
  • · Z (S) $7000

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 18, 2012
Abate by
Nov 8, 2012
Penalty
Initial $5,000 · Current $3,500 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.     On the Kill floor, employees working next to the split-saw platform were exposed to crush-by hazards in that a guard system was not in place to keep employees from walking beneath the split saw platform.
Recent events (2)
  • · I (S) $3500
  • · Z (S) $5000

1910.219 F03

Serious Gravity 1 2 instances 2 exposed
Issued
Oct 18, 2012
Abate by
Nov 8, 2012
Penalty
Initial $3,000 · Current $2,500 Reduced
29 CFR 1910.219(f)(3): All sprocket wheels and chains shall be enclosed unless they are more than seven (7) feet above the floor or platform. Where the drive extends over other machine or working areas, protection against falling shall be provided.     In the Rendering Room, employees were exposed to amputation hazards. The employees were exposed in that the chain and sprockets at the Server-tex feed auger and the Server-tex Discharger were not completely guarded.
Recent events (2)
  • · I (S) $2500
  • · Z (S) $3000

1910.178 A06

Other-than-serious 3 instances 3 exposed
Issued
Oct 18, 2012
Abate by
Oct 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(6): The user shall see that all nameplates and markings are in place and are maintained in a legible condition.    Employees were operating forklifts that did not have adequate markings on the control levers; the forklifts were identified as 18, 22, and 15.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.219 C04 I

Other-than-serious 1 instance 2 exposed
Issued
Oct 18, 2012
Abate by
Oct 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves.    In the Processing Floor at the trim belt a projecting shaft was more than one-half the diameter of the shaft. The diameter was approximately 1 inch and projected approximately 2 inches
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.305 G01 IV B

Other-than-serious 2 instances 2 exposed
Issued
Oct 18, 2012
Abate by
Oct 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B): Unless Specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords may not be used; Where run through holes in walls, ceilings, or floors.    In the ABS Maintenance Shop, flex cords were extending through walls located:     a) On the main brick wall energizing a clock.    b) Through a metal cabinet energizing a small battery charger.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View National Beef's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 334803392.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.