Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DEPARTMENT OF INTERIOR, BUREAU OF RECLAMATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DEPARTMENT OF INTERIOR, BUREAU OF RECLAMATION in BUILDING 1400, BOULDER CITY, NV 89005 (NAICS 921110). OSHA activity number 334838984.

Watch Department OF Interior, Bureau OF Reclamation — free Get an email when a new federal OSHA severe-injury report for Department OF Interior, Bureau OF Reclamation is published. One employer, no account, unsubscribe in one click.
Site address
BUILDING 1400
City
BOULDER CITY
State
NV
ZIP
89005
Mailing
500 FIR STREET, BOULDER CITY, NV 89005
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
921110
Employees
850
Ownership type
D

5 citations on file for this inspection.

1910.36 G02

Serious Gravity 1 1 instance 5 exposed
Issued
Sep 19, 2012
Abate by
Sep 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2):   Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.    (a)  Bureau of Reclamation, Building 1400, back storage area next to engineers cubicle; exit access was 17 inches and obstructed by boxes and furnitures.
Recent events (1)
  • — Z (S) $0

1910.37 B02

Serious 2 instances 120 exposed
Issued
Sep 19, 2012
Abate by
Sep 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2):   Each exit was not clearly visible and marked by a sign reading "Exit":    (a)  Bureau of Reclamation, Building 1400, first floor break room exit door did not have an "EXIT" sign.
Recent events (1)
  • — Z (S) $0

1910.304 B03 II A

Serious Gravity 5 1 instance 40 exposed
Issued
Sep 19, 2012
Abate by
Sep 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.304(b)(3)(ii)(A):  All 125-volt, single-phase, 15, 20 and 30-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by personnel did not have ground-fault circuit-interrupter protection for personnel.    (a)  Bureau of Reclamation, Building 1400, environmental library cubicle 222K, the Hi-Saver multiple outlet surge protector was used to provide power to cubicle outlets and extension cord without a ground fault circuit interrupter for personnel protection.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 80 exposed
Issued
Sep 19, 2012
Abate by
Sep 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A):   Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.    (a)  Bureau of Reclamation, Building 1400, a yellow flexible cord was used as a substitute for fixed wiring for the mechanical file room.
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 8 exposed
Issued
Sep 19, 2012
Abate by
Sep 24, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii):   Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws.    (a)  Bureau of Reclamation, Building 1400, environmental library cubicle 222K; the male end of the flexible electric cord did not have strain relief and insulation was pulled away from the outer sheath.
Recent events (1)
  • — Z (S) $0

View Department OF Interior, Bureau OF Reclamation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334838984.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.